Specifications
Appendix B. Entering SDI-12 Commands/Changing Settings 
•  0 (OFF—this mode is typically not recommended; sensor is completely off 
until a new set power command is received) 
The OFF power mode should only be used by advanced users 
who want to turn the sensor off for extended time periods.  In this 
mode the sensor is completely off and only responds to a new set 
power command. 
CAUTION 
The factory default Power Operation Mode is 1 (ON). In this mode of 
operation, the instrument is continuously making measurements and draws 
approximately 13.5 mA. The AUTO Power Operation Mode puts the 
instrument in quiescent mode between measurement request queries. 
Change this setting by first using the aXSPOM+n! command (where n=1 (on), 
2 (auto), or 0 (off)) followed by the aXGPOM! (Get Power Mode) command. 
Table B-6 shows an example of the command and response for changing this 
setting. 
TABLE B-6. Example for Setting Power Operation Mode 
Initial Command  Response 
0XSPOM+2! 
Where, 
0—sensor’s address; 
2—the new power mode setting 
(2=auto). 
00011<cr><If> 
Where (from left to right), 
0—sensor’s address; 
001—the amount of time (in seconds) 
that you must wait before sending 
another data command; 
1—the number of values that will be 
placed in the buffer. 
Subsequent Command  Response 
aXGPOM! 
Where zero is the sensor address. 
This is the get power mode 
command. 
0+2<cr><If> 
Where, 
0—sensor’s address; 
2—the new power mode setting 
(2=auto). 
B-5 