User manual

Table Of Contents
MetPak Doc No 1575-PS-0001 Issue 02 CN 4240 March 2006
Option 6
1575-PK-006
WindSonic for MetPak
White WindSonicWindspeed & Direction, sensor fitted with cable and
aspiration shield mounting adaptor and analogue output. Distributor to
mount on their own aspiration shield and fit their own probe.
4.2 Specification
Wind Sensor
Output
Units of measure Metres/second (m/s), Knots, Miles per hour (mph),
Kilometres per hour (kph), Feet per minute (fpm)
Output frequency 1, 2, or 4 outputs per second
Digital Analogue
Parameters
or
Polar - Speed and Direction
UV - 2 axis, signed Speed
Polar - Speed and Direction
Tunnel - U Speed and U Direction
Wind Speed
Range 0 – 60 m/s 0 – 30m/s, 0 – 50m/s, 0 – 60m/s,
Accuracy
± 2% (12m/s) ± 2% (12m/s)
Resolution 0.01 m/s 0.01 m/s
Wind Direction
Range
0 - 359° 0 - 359
°
or 0 - 539° (Wraparound mode)
Accuracy
± 3° (20m/s) ±3° (20m/s)
Resolution
1° 1°
Output formats
0-5V
Data Logger
± 1% of full scale N.B. Analogue output impedance = 1K
SDI-12 V1.3
Anemometer status
Status OK and Error codes included as part of output message from
RS232 programming port.
Environmental
Moisture protection IP65
Temperature
Operating -35°C to +70°C Storage -40°C to +80°C
Humidity Operating <5% to 100%
EMC EN 61000-6 - 3 (Emissions)
EN 61000-6 - 2 (Immunity)
Standards
Manufactured within ISO9001: 2000 quality system
8