User manual
Table Of Contents
- 1 FOREWORD
- 2 INTRODUCTION
- 3 PRINCIPLE OF OPERATION
- OPTIONS AND SPECIFICATION
- INSTALLATION REQUIREMENTS
- INSTALLATION
- 7 MECHANICAL
- 8 OUTPUT FORMATS
- 9 ANALOGUE OUTPUTS AND OPTIONS
- 10 METPAK SDI-12
- 11 MAINTENANCE & FAULT-FINDING
- 12 TESTS
- 13 APPENDICES
- CS215_jun06.pdf

MetPak Doc No 1575-PS-0001 Issue 02 CN 4240 March 2006
TB3 TB1
Connections from WindSonic
Connections from Rotronic
Temperature and Relative Humidity
Senso
r
Outputs to Customer Equipment
TB2 TB4
Connecting to an SDI-12 Interface (Option 1 and 2)
TB 3 Junction Box
10 Way Terminal Block
Data logger or
Chart recorder
Signal names Signal names
Signal GND
V-
V+
TXD-
RXD-
3
10
9
1
2
GND
+V (9-16Vdc)
Serial Data Line
Note: SW1 must be in closed position for SDI-12 option. If you wish to use RS232 programming port then SW1 must be
in open position and only external links between TXD- and RXD- must be temporarily removed.
TB1 TB3
Connections from WindSonic
Connections from Campbell
SDI12 Temperature and
Relative Humidity Sensor
Ouputs to Customer
Equipment
TB2 TB4
14