5. LoggerNet Configuration
5.1 Setup of Loggernet Communications
This Section deals with the proper software setup of a remote station that is making
use of the COM9522B, in Campbell Scientific’s LoggerNet datalogger support
software. All screenshots are based on the CR1000 datalogger. Please note that the
array based dataloggers (i.e. CR10X) can also be configured in a similar fashion in
LoggerNet.
5.1.1 Step 1: LoggerNet Setup
Start the LoggerNet software package and open the Setup applet from the main menu.
Start the configuration by clicking on the Add Root button. From the “Add” submenu
make the following selections:
ComPort
Generic
PakBusPort
CR1000
Finally click the close button in the “Add” submenu. Your setup tree should appear
as in Figure 15.