User guide

9522B & COM9522B Iridium Data Modem
2
Table 1. Equipment List for Base and Remote Stations
Base Station
Remote Station
9522B L-Band Data Modem
9522B L-Band Data Modem
MB3 Mounting Kit (optional)
Iridium antenna plus cable
Iridium antenna plus cable
COM9522B
COM9522B
Iridium SIM card (comes with modem)
Iridium SIM card (comes with modem)
9876-001 Null Modem Cable (1ft lead)
SC932A with an extra SC12 (Only required if
using CSI/O port of datalogger)
SC110 9-pin male DTE to bare leads (Only
required if using a datalogger COM Port)
1.3 Hardware Overview
Table 1 lists the hardware typically used for both a Base and Remote station. Tables
2 and 3 list common wiring for both the remote and base stations. Figures 1 to 3
represent the typical configurations of the Base and Remote stations. Please refer to
Appendix B for a thorough description of the installation procedure for both the Base
and Remote stations.
Be sure that the antenna is connected to either of the
modems before applying power, as damage to the
equipment may occur.
Table 2. Remote Station COM9522B Wiring
Hardware
ComPort
Description
Colour
Connection
9522B
Antenna
“ANT” SMA connector to antenna cable
using C2626 adaptor
COM9522B Interface
26-pin ribbon cable connector
COM9522B
Power Control
Yellow
Control Port Datalogger (5V power
trigger)
Ground
Black
G Datalogger
Modem Power
Red
+12V (Direct to Station Power Supply)
9876-001
RS232
Serial Communications
9876-001
9-pin connector of COM9522B
SC932A
(optional)
CS I/O
“DCE Device”
SC12
9-pin connector of COM9522B
“Datalogger”
SC12
CS I/O port of Datalogger
WARNING