Instruction manual

9522B Iridium Satellite Modem and COM9522B Interface Modem
5.1.6 Step 6: CR1000 Configuration
Select your datalogger as shown in FIGURE 5-6. Be sure that the
Communications Enabled box is checked and that the PakBus Address is
correct for the datalogger being used. Set the Delay Hangup to 200 ms.
FIGURE 5-6. CR1000 Hardware Configuration
Select the Schedule tab and configure the Collection Interval as required for
your application. Be sure that the Scheduled Collection Enabled box is
checked. FIGURE 5-7 shows an example of a daily scheduled data collection
that is to start at 1:00pm. The number of retries and the retry interval are left in
their default state in the example. These values should be adjusted as required.
Once all configurations are complete, click the Apply button in the lower left
hand corner. The station is now set up in LoggerNet.
17