5.1.2 Step 2: ComPort Configuration
With the setup tree entered, you will now need to complete the configuration of
each element. Start with selecting the ComPort element at the root of the tree
(FIGURE 5-2). Be sure that the ComPort Connection is correct for the
computer used as part of your base station, and make sure that the
Communications Enabled box is checked.
Set the Extra Response Time and ComPort Communication Delay to 3
seconds. Set the Delay Hangup to 200 ms. This will prevent LoggerNet from
hanging up whenever there is a slight lag in transmission time, which is
common in satellite applications.
FIGURE 5-2. ComPort Configuration