User`s guide
Call-Back Configuration for the CR800/CR1000 – MultiLogger Application Note #19 – Page 9 of 12
MultiLogger After Call-back Do Configuration
Call-back initiates a data collection from the called computer running MultiLogger. Notification can be
provided in several ways to provide reporting of the call-back events. This includes:
• When using MultiLoggerDB, email messages to include specific Output Parameters defined in the
database such as Quick Reports, Quick Charts or Spreadsheets can be sent. Also, paging, digital
I/O operations such as a activating an attached light or siren, or program execution can be
initiated. See the Insite Users Guide section 3.10 in regards configuring the Notification Events.
• Use the Logger form Configure | Notification System form to configure emailing of arrays
including alarm arrays or specific elements from the alarm arrays. See the MultiLogger Users
Guide section 6.10 for more information on using the Configure | Notification System form.
• Execution of call-back tasks configured in the Network Configuration. These can include batch
files for executing multiple applications or tasks, automated delivery of data files through email or
ftp, or execution of any user supplied program residing on the Gateway PC. These are After Call-
back Do Tasks configured in the Network Configuration.
Note: When using the Configure | Notification System options to generate emails as a result of
call-back events MsgServer must be running the gateway PC to facilitate sending the emails. See
FAQ #22 available in the Support area of our website at www.canarysystems.com for information
on using and configuring MsgServer to send emails.
This section will detail the setup for using the After Call-back Do functionality.
Select the Gateway to add the Task. Press the Add button to display the Add new Gateway or Device
form. Select Task as shown below. Press Accept.