FIGURE 4. CR10X with CR10 Wiring Panel and COM220 Using RJ11C Telephone Jack
3.2 Connecting to Earth Ground
Connect the green 14 awg grounding wire (provided with the COM220) to the
ground terminal (GND) on the COM220 and to the enclosure’s earth ground
connection. If the site does not have a grounded enclosure, then connect the
ground wire directly to an earth ground connection. The datalogger ground
should also be tied to the earth ground (see Figures 3 and 4).
The modem must be grounded for its transient protection
to work.
CAUTION