Specifications

User Manual
3
5. Specifications
Compatibility: CR800 (not CR850)
CR1000
CR3000
Interface: CS I/O, SDC address 2
Temperature
Operating: -45° to 85°C
Storage: -50° to 85°C
Transit: 1 hour at -60°C
Power Requirement
Source: 12 VDC from datalogger CS I/O port
Current Draw
Inactive: 0.02 mA
Active: 140 mA
Features:
Operable with gloved hand
16 key alpha numeric keypad
8 line x 21 character display (64 x 128 pixel)
Certification: CE Compliant
Rating
Water and dust ingress
Installed as recommended: IP66
Uninstalled: None (vulnerable to water and dust)
Weight: 0.36 kg (0.80 lbs)
Dimensions: 176 x 138 x 8 mm (6.9 x 5.4 x 1.4 in)
6. Installation
As a purchased service, Campbell Scientific offers the option of
installing the CD100 into an enclosure.
Install only on a flat, non-porous surface. The supplied gasket must create a
weather-tight seal when installed or permanent damage to the display and other
enclosure contents may occur.
1. Use the template shipped with the CD100 or create a template using the
measurements shown in Figure 2. Template Measurements.
2. Make the required cuts in the bulkhead.
3. Remove cutting debris from bulkhead.
4. Mount the CD100 as shown in Figure 3. Profile of Installed CD100.
5. Before tightening screws, adjust the gasket to align it just inside the edges
of the display. Uniformly tighten the screws, but do not over-tighten.
NOTE