Specifications
CC640 Digital Camera
3. Camera Hardware Description
3.1 Terminal Block Connections
Only shielded cable should be used for connections to the
terminal block.
NOTE
Gnd Power Ground
+12VDC 9-15VDC Power, 250 mA
Ext. External Trigger Input, 5.0 Volt Logic Signal, 15Volts Max
RS-485A RS-485 communication
RS-485B RS-485 communication
Shield The shield (drain wire) needs to be connected to this terminal
FIGURE 2. Terminal Block Position and Layout
3.2 Power Switch
The power switch can be used to power the camera continuously on or to place
the camera in Auto power mode. The switch should not be left in the On
position under normal operation. Leaving the switch in the On position will
prevent the camera from entering its low power quiescent mode of operation.
The power switch does need to be placed to the On position to perform
configuration setup or to focus the camera.
In the Auto position the camera will automatically reduce its power
consumption to the low power quiescent mode after an image is acquired. It is
5