SPECIALIZED TECHNOLOGIES FOR INDUSTRIAL SUPPLIES CO. LTD شركـة التقنيات المتخصصة لـلـتجھيــزات الـصناعـية الـمحــدودة شركة ﺫات ﻤﺴﺌوﻝﻴﺔ ﻤﺤدودة Limited Liability Company :رأس المال المدفوع PAID UP CAPITAL: SR 500 000 PROJECT PURCHASE & INSTALL WEATHER MONITORING STATIONS CONTRACT # 30531212/00 P.O. Box 31501, Al- Khobar 31952 – Saudi Arabia - Tel: (+966 3)8147147-Fax: (+966 3)8147149 – C.R.2051025629, Email: sales@stisco.com – Website: www.stisco.
INDEX / CONTENTS I. DRAWINGS............................................. a. Pole Mounting Details b. Location Details c. Weather Station Enclosure Drawing d. Weather Station Enclosure Wiring e. Sensor Wiring Diagram II. POLE MOUNT DETAILS........................... III. DATASHEETS...........................................
I - DRAWINGS
TYPICAL ENCLOSURE WIRING AL KHARJ 9003
TYPICAL ENCLOSURE WIRING AL KHARJ 9003
TYPICAL ENCLOSURE WIRING AL KHARJ 9003
II - MOUNTING OPTIONS
MOUNTING OPTIONS The Weather Monitoring Stations that are being installed provide the flexibility of being mounted in several ways. Mounting can be done via a 10m Tower, a Tripod or most conveniently by Pole mount. Unlike the Tower and Tripod installations the Pole mount is light in weight, requires no excavation or underground cable laying and no modifications to existing Plant. The Pole mount installation consists of a pole mounted via application specific brackets to a predetermined wall.
III - DATASHEETS
WEATHER MONITORING STATION (POLE MOUNTED) - EQUIPMENT WEIGHT NO. MODEL NO. ITEM DESCRIPTION 1 2 3 4 5 6 7 N/A CS106 NL120 SDM-AO4A CR1000 PS100 WindSonic1 8 9 10 11 12 HC2S3 CM206 CC5MPX 14014 ENC16/18 13 14 15 16 N/A N/A N/A N/A QTY WEIGHT (g) TOTAL (g) PLUG SOCKET WITH DIN RAIL 1 260 BAROMETER/PRESSURE SENSOR 1 90 ETHERNET INTERFACE UNIT 1 66.
ENC-Series Weather-Resistant Enclosures Models Available ENC10/12 Campbell Scientific’s ENC10/12 enclosure has internal dimensions of 10 x 12 x 4.5 in. (25.4 x 30.5 x 11.4 cm) and weighs 9.0 lb. (4.1 kg). It can house one CR200(X)-series datalogger, power supply, and one small peripheral. A CR800, CR850, or CR1000 can also be housed in the ENC10/12 if the #17565 stack mounting kit is used.
Mounting Bracket Options Tripod Order the -MM option if you want to mount your enclosure to the mast of one of our tripods or to a usersupplied pipe with a 1.25-in to 2.1-in OD. A threepiece bracket attaches to the top of the enclosure and an identical three-piece bracket attaches to the bottom of the enclosure (see illustrations at right). Each bracket is attached to the mast or pole via a 2-in u-bolt. At left is an enclosure with the -MM mount option.
Cable-Entry Options Conduit(s) Multiple cables can be routed through one conduit. The -SC option provides one 1.5-in. diameter conduit; the -DC option provides two horizontally-arranged 1.5-in. diameter conduits; and the -VC option (ENC16/18 only) provides two vertically-arranged 1.5-in. diameter conduits. A plug included in the 7363 enclosure supply kit can reduce the conduit’s internal diameter to 0.5 in. (1.3 cm). The enclosure supply kit also contains the putty used to seal each conduit.
CD100 Mountable Display with Keypad Specify #27814 to have Campbell Scientific install a CD100 in the enclosure door. The CD100 is an integrated keypad with display that mounts in an enclosure lid, which allows you to enter and view data without opening the enclosure. The CD100 provides the same operation and functionality as the CR1000KD, and is typically used with our CR800 and CR1000 dataloggers.
CC5MPX & CC5MPXWD High Resolution Digital Network Cameras The CC5MPX and CC5MPXWD are high-resolution digital cameras with video capabilities. They produce JPG images with a resolution of up to 5 megapixels, and shoot videos with a resolution of up to 720P. Power conserving modes allow the cameras to be used in remote battery-powered installations. The CC5MPX and CC5MPXWD have several options for image acquisition and storage.
Ordering Information Specifications Operating Power CC5MPX: CC5MPXWD: Digital Cameras CC5MPX CSC High Resolution Digital Network Camera (-40° to +60°C) CC5MPXWD CSC High Resolution Digital Network Camera with window defroster (-40° to +60°C) 9 to 30 Vdc 9 to 16 Vdc Current Drain Operating (camera only): Quiescent: CC5MPXWD defroster on: Memory Option (choose one) 250 mA (maximum at 12 Vdc) ≤1 mA (off power mode) 1.
CR1000 measurement & control datalogger A rugged instrument with research-grade performance.
CR1000 Measurement and Control System The CR1000 provides precision measurement capabilities in a rugged, battery-operated package. It consists of a measurement and control module and a wiring panel. Standard operating range is -25° to +50°C; an optional extended range of -55° to +85°C is available. Input/Output Terminals— Individually configured for ratiometric resistive bridge, thermocouple, switch closure, high frequency pulse, low-level ac, serial sensors, and more.
Analog Inputs Eight differential (16 single-ended) channels measure voltage levels. Resolution on the most sensitive range is 0.67 µV. Communication Protocols Pulse Counters Two pulse channels can count pulses from high level (5 V square wave), switch closure, or low level AC signals. The CR1000 supports the PakBus, Modbus, DNP3, TCP/IP, FTP, and SMTP communication protocols. With the PakBus protocol, networks have the distributed routing intelligence to continually evaluate links.
Data Storage and Retrieval Options To determine the best option for an application, consider the accessibility of the site, availability of services (e.g., cellular phone or satellite coverage), quantity of data to collect, and desired time between data-collection sessions. Some communication options can be combined—increasing the flexibility, convenience, and reliability of the communications.
Channel Expansion 4-Channel Low Level AC Module The LLAC4 is a small peripheral device that allows customers to increase the number of available lowlevel ac inputs by using control ports. This module is often used to measure up to four anemometers, and is especially useful for wind profiling applications. Synchronous Devices for Measurement (SDMs) SDMs are addressable peripherals that expand the datalogger’s measurement and control capabilities.
Applications The measurement precision, flexibility, long-term reliability, and economical price of the CR1000 make it ideal for scientific, commercial, and industrial applications. Meteorology The CR1000 is used in long-term climatological monitoring, meteorological research, and routine weather measurement applications. Wind Profiling Our data acquisition systems can monitor conditions at wind assessment sites, at producing wind farms, and along transmission lines.
Air Quality The CR1000 can monitor and control gas analyzers, particle samplers, and visibility sensors. It can also automatically control calibration sequences and compute conditional averages that exclude invalid data (e.g., data recorded during power failures or calibration intervals). Vehicle Testing This versatile, rugged datalogger is ideally suited for testing cold and hot temperature, high altitude, off-highway, and cross-country performance.
CR1000 Specifications Electrical specifications are valid over a -25° to +50°C range unless otherwise specified; non-condensing environment required. To maintain electrical specifications, Campbell Scientific recommends recalibrating dataloggers every two years. We recommend that the system configuration and critical specifications are confirmed with Campbell Scientific before purchase.
CS106 Barometric Pressure Sensor The CS106 barometer uses Vaisala’s BAROCAP silicon capacitive sensor to measure barometric pressure over a 500 to 1100 millibar range. The CS106 outputs a linear signal of 0 to 2.5 Vdc, allowing it to be directly connected to Campbell Scientific dataloggers. The CS106 is compatible with all of our contemporary dataloggers and many of our retired dataloggers (e.g., CR510, CR10(X), CR23X).
COMPONENTS HC2S3 Temperature and RH Sensor The HC2S3 is a rugged, accurate temperature/RH probe that is ideal for long-term, unattended applications. The probe uses a Rotronic’s IN1 capacitive sensor to measure RH and a 100 ohm PRT to measure temperature. For optimum results, the HC2S3 should be recalibrated annually. The HC2S3 comes with a polyethylene filter that protects its sensor from fine dust and particles and minimizes water absorption and retention.
Specifications Electronics Operating Limits: -40° to +100°C Storage Temperature: -50° to +100°C Temperature Accuracy Graph +0.6 Dimensions Diameter: Length: 15 mm (0.6 in.) 168 mm (6.6 in.) Weight: 10 g (0.35 oz) Filter: Polyethylene or Teflon Current Consumption: <4.5 mA @ 3.3 Vdc <4.3 mA @ 5 Vdc <2.0 mA @ 12 Vdc +0.4 Supply Voltage: 5 to 24 Vdc Maximum Startup Current: <50 mA for 2 µs Accuracy °C +0.2 0 -0.2 -0. 4 -0.6 -0.8 -1.
Instrumentation Mounts Crossarms, Solar Radiation Mounts, Radiation Shields Campbell Scientific offers a variety of instrument mounts to attach sensors and peripherals to our lightweight tripods (CM110, CM115, CM120), galvanizedsteel tripods (CM6, CM10), and towers (UT10, UT20, UT30). This equipment includes crossarms, brackets, solar radiation sensor mounts, and radiation shields.
CM210 Crossarm Mounting Kit The CM210 is included with our CM202, CM204, and CM206 crossarms but may also be ordered separately. When attaching a crossarm to a tower, purchasing a second CM210 may be desirable to secure the crossarm to two of the three tower legs. The CM210 is shipped with two 1.5-in. u-bolts and two 2-in. u-bolts allowing it to be attached to any of our tripods or towers. Mast CM204 Crossarm SPECIFICATIONS Top right is the front side of the CM210 showing the bracket and u-bolts.
CM230 Adjustable Inclination Mount The CM230 is primarily used with directional (Yagi) antennas, but can also be used with sensors that need to be pointed at a specific target (e.g., SI-111, SR50A). When using the CM230, fix the declination of the antenna or sensor by tightening a 2-in. u-bolt that mounts on the mast or user-supplied pipe. The inclination is then adjusted with a 1.5-in. u-bolt and nuts. The CM230 weighs 0.75 lbs (0.34 kg); dimensions are 3.0 x 3.75 x 3.5 in. (7.62 x 9.53 x 8.89 cm).
Radiation Shields for Temperature and Temperature/RH Probes Naturally-Aspirated Radiation Shields Campbell Scientific offers six-plate, 10-plate, and 14plate naturally-aspirated radiation shields. The diameter of each plate is 4.7 in. (11.9 cm). Their louvered construction allows air to pass freely through the shield, thereby keeping the probe at or near ambient temperature. These radiation shields mount to a crossarm, mast, or tower leg via a 2-in. u-bolt with a plastic v-block.
NL120 10baseT Ethernet Module Campbell Scientific’s NL120 allows a CR1000 or CR3000 datalogger to communicate over a local network or a dedicated Internet connection via TCP/IP. This 10baseT Ethernet module connects directly with the 40-pin peripheral port on a CR1000 or CR3000. It is the smallest Ethernet module available for those dataloggers. A 10baseT Ethernet straight through cable is used when the cable is run from a hub to the NL120.
Specifications Power: 12 V supplied through the datalogger’s peripheral port Current Drain: 20 mA EMI and ESD Protection: Meets requirements for a class A device under European Standards Application of Council Directive(s): 89/336/EEC as amended by 89/336/EEC and 93/68/EEC Standards to which conformity is declared: EN55022-1; 1995 and EN50082-1: 1992 Temperature Range: -25° to +50°C standard; -40° to +85°C extended Software Requirements: • LoggerNet 3.2 or later • PC400 1.3 or later • DevConfig 1.
BPALK and PS100 Power Supplies for CR800, CR850, and CR1000 The BPALK and PS100 are 12 Vdc power supplies for our CR800, CR850, CR1000, CR10X, CR510, or CR500 dataloggers, and peripherals. They can also be used as a separate auxiliary 12-V power supply to power remotely located sensors or peripherals, such as a multiplexer located at a distance from the datalogger enclosure. However, to avoid errors in analog measurements and ground loops, the power supplies must share a common ground.
Ordering Information Specifications* BPALK Alkaline Battery Pack Power Supplies BPALK 12 V, 7.5 Ahr Alkaline Battery Pack PS100 12 V Power Supply with Charging Regulator and 7Ahr Sealed Rechargeable Battery Adapters for the PS100 Nominal Rating: 7.5 Ahrs @ 20°C Batteries: 8 Alkaline D cells (not rechargeable) Output Voltage: 12 Vdc 1.8 kg A100 Null Modem Adapter Weight: A105 12 V Terminal Expansion Adapter Dimensions (including mounts and connectors): 7.1” x 2.9” x 3.1” (18.1 x 7.4 x 8.
SDM-AO4A Four-Channel Analog-Output Module The SDM-AO4A provides four independent, continuous, analog outputs for proportional control or driving strip charts. Measured or processed values in the datalogger are scaled to millivolts and transferred to the SDM-AO4A as digital values. The SDM-AO4A then performs a digital to analog conversion and outputs an analog voltage signal. The output voltage level is maintained until it is updated by the datalogger.
Specifications Physical Power Requirements Operating Temperature: -40° to +60°C Operating Voltage: Dimensions: 5.3 x 3.35 x 0.95 in. (13.46 x 8.51 x 2.41 cm) Typical Current Drain Weight: Voltage Range: ±5 V or 0 to 10 V Resolution: 0 to 10 V Mode No load, Vout =0, Vsupply = 12 V 11 mA 21 mA No load, Vout =Fullscale, Vsupply = 12 V 13 mA 28 mA With load, Vsupply = 12 V 13 mA + load 28 mA + (2.
COMPONENTS HC2S3 Temperature and RH Sensor The HC2S3 is a rugged, accurate temperature/RH probe that is ideal for long-term, unattended applications. The probe uses a Rotronic’s IN1 capacitive sensor to measure RH and a 100 ohm PRT to measure temperature. For optimum results, the HC2S3 should be recalibrated annually. The HC2S3 comes with a polyethylene filter that protects its sensor from fine dust and particles and minimizes water absorption and retention.
Specifications Electronics Operating Limits: -40° to +100°C Storage Temperature: -50° to +100°C Temperature Accuracy Graph +0.6 Dimensions Diameter: Length: 15 mm (0.6 in.) 168 mm (6.6 in.) Weight: 10 g (0.35 oz) Filter: Polyethylene or Teflon Current Consumption: <4.5 mA @ 3.3 Vdc <4.3 mA @ 5 Vdc <2.0 mA @ 12 Vdc +0.4 Supply Voltage: 5 to 24 Vdc Maximum Startup Current: <50 mA for 2 µs Accuracy °C +0.2 0 -0.2 -0. 4 -0.6 -0.8 -1.
WindSonic1, WindSonic4 2-D Ultrasonic Anemometers The WindSonic1 and WindSonic4 are two-dimensional ultrasonic anemometers for measuring wind speed and wind direction. They provide an alternative to traditional mechanical cup and vane or propeller and vane anemometers. Unlike mechanical anemometers, there are no moving parts to be periodically replaced— minimizing routine maintenance costs. These twodimensional anemometers are manufactured by Gill Instruments, Incorporated.
Specifications Operating Humidity: 0% to 100% RH Temperature Range Operating: Storage: -35º to +70ºC -40º to +90ºC Input Voltage: 9 to 30 Vdc Typical Current Drain WindSonic1: WindSonic4: ~15 mA continuous ~23 mA continuous 5.6 in (14.2 cm) 6.3” in (16.0 cm) Weight: 1.1 lbs (0.