Instruction manual

9522B Iridium Satellite Modem
_____________________________________________________________________________
23
Problem: Loggernet makes several attempts to connect to the
remote station with no success. The failure is not immediate and
the Loggernet LogTool may show a “No Carrier Detected” error.
Solution: It is possible that the base modem has lost it’s
configuration. Resend the configuration as shown in Section 2.2
of this manual and attempt communications again.
Problem: I am using Iridium to communicate through the CS I/O
port on my datalogger. Whenever I try connecting with the
datalogger LoggerNet reports that communication with the
station has failed. This message takes several seconds to
appear.
Solution: You may have connected your SC932A device
backwards at the remote station. When you install the SC932A it
is imperative to make sure that the device is connected in the
proper way. Follow the label on the device for the proper
connections.