16
3.1.2. Step 2: ComPort Configuration
With the Setup tree entered, you will now need to complete the
configuration of each element. Start with selecting the ComPort
element at the root of the tree (Figure 15). Be sure that the
Com Port Connection is correct for the computer used as part of
your Base Station, and make sure that the Communications
Enabled box is checked. Under Delay Hangup, add a delay of
200 ms. This will prevent LoggerNet from hanging up whenever
there is a slight lag in transmission time, which is common in
Satellite applications.
Figure 15: ComPort Configuration
3.1.3. Step 3: PhoneBase Configuration
Select the PhoneBase element as in Figure 16. Be sure the
Communications Enabled box is checked. Adjust the Maximum
Baud Rate to 19200 Baud (9600 for a CR10X) and add a 200 ms
delay. You will need to configure a custom modem initialization
string for use with the base modem. Click the Edit Modem
Database button. Click the New button, name the string, leave
the Reset string blank, and insert only &C0 as the initialization
string. Be sure to save the new string (Steps not shown). Move
to the PhoneRemote element once complete.