Specifications

41
Alias ParseStr(8) = NUMSATS
Alias ParseStr(9) = HDP
Alias ParseStr(10) = ALTDE
Alias ParseStr(11) = ALTUNIT
Alias ParseStr(12) = GIODAL
Alias ParseStr(13) = GEOUNIT
Alias ParseStr(14) = AGE
Alias ParseStr(15) = DIFFREF
Alias ParseStr(16) = ASTERISK
Alias ParseStr(17) = CHCKSUM
Alias ParseStr(18) = CRLF
Units Batt_VoltI=Volts
Units Batt_VoltF=Volts
Units Batt_V_Drop=Volts
Units PTemp_C=Deg C
Units WS_ms=meters/second
Units WindDir=Degrees
Units BP_mmHg=mV (mmHg)
'Units WaterColumnPressure=mV/V
Units AS_T=mV
Units AS_RH=mV
Units AS_Pt100=mV?
Units US_T=mV
Units US_RH=mV
Units US_Pt100=mV?
Units Xtilt=mV
Units Ytilt=mV
Units TermStringT(8)=Deg C
Units CNR1_SWin=mV
Units CNR1_SWin =mV
Units CNR1_SWout=mV
Units CNR1_LWin=mV
Units CNR1_LWout=mV
Units CNR1_Pt100=mV
'Define Data Tables
DataTable (InstantaneousTable,True,1)
Sample(1,BP_mmHg,FP2)
Sample(1,AS_Pt100,FP2)
Sample(1,AS_T,FP2)
Sample(1,AS_RH,FP2)
WindVector (1,WS_ms,WindDir,FP2,False,0,0,0)
Sample(1,InstantDataTerminator,String)
EndTable
DataTable(TxBufferTable,True,SummerTableBuffer)
Sample(1,TxBufferString, String)
EndTable
DataTable(TableSummerTx,True,1,)'SummerTableBuffer)'then, size = 1
DataInterval(0,SummerTxRate*ScanRate,Sec,1)
Average(1,BP_mmHg,FP2,False)
' StdDev(1,BP_mmHg,FP2,False)
Average(1,AS_Pt100,FP2,False)
' StdDev(1,AS_Pt100,FP2,False)
Average(1,AS_T,FP2,False)'AS_ = Rotronics Aspirated Shield
' StdDev(1,AS_T,FP2,False)
Average(1,AS_RH,FP2,False)' This is conceptually wrong
' StdDev(1,AS_RH,FP2,false)' This is conceptually wrong
WindVector (1,WS_ms,WindDir,FP2,False,0,0,0)
FieldNames("WS_ms_S_WVT,WindDir_D1_WVT,WindDir_SD1_WVT")'From manual:"Mean hori