Specifications

24
MULTIPLEXER
(it must be configured as a 4x16 MUX)
Multiplexer side Device side Device name
CONTROL
&
POWER
RES C1 CR1000
CLK C2 CR1000
GND G CR1000
12V SW-12V DISTRIB. PANEL SW-12V DISTRIB. PANEL
COMMON
ODD
H SE13 CR1000
L SE14 CR1000
GND GND (between SE14 - SE15) CR1000
EVEN
H SE15 CR1000
L SE16 CR1000
GND open
1
1
H GRE Setra Barometer
L GRE Young wind
GND open
2
H open
L open
GND WHI, shield Youn
g
wind
2
3
H
current sense shunts, post 13 Battery low side current sensing R hi
L
current sense shunts, post 14 Battery low side current sensing R lo
GND open
4
H ORA Termistor string level 1
L BLK Termistor string level 2
GND o
p
en
3
5
H
current sense shunts
,
p
ost 9
S
olar
p
anel low side current sensin
g
Rhi
L
current sense shunts, post 10 Solar panel low side current sensing R lo
GND open
6
H
BL
U
Termistor strin
g
level 3
L
YEL Termistor strin
g
level 4
GND open
4
7
H
current sense shunts
,
p
ost 6
F
an low side current sensin
g
R hi
L
current sense shunts
,
p
ost 5
F
an low side current sensin
g
R lo
GND open
8
H
GRE Termistor string level 5
L
BRO Termistor strin
g
level 6
GND open
5
9
H
current sense shunts, post 2 Iridium low side current sensing R hi
L
current sense shunts
,
p
ost 1
I
ridium low side current sensin
g
R lo
GND open
10
H
PNK Termistor strin
g
level 7
L VIO Termistor string level 8
GND open
6
11
H YEL Tilt sensor
L GRE Tilt sensor
GND GRY Tilt sensor
12 H open