4. Maintenance 
An occasional cleaning of the glass improves the solar panel's efficiency. If a 
problem with the solar panel is suspected, the panel may be checked by 
measuring the voltage output. Check the voltage with a voltmeter connected 
between the two leads of the solar panel. There must be solar radiation 
incident on the panel and there must be a load connected to the solar panel. 
The load can be the datalogger, other equipment, or a 75 ohm resistor capable 
of dissipating solar panel power between the two leads. No voltage output 
implies a bad solar panel, regulator, or cable. The magnitude of the voltage 
output depends on the incident solar radiation. 