SC532A 9-Pin Peripheral to RS232 Interface Revision: 4/09 C o p y r i g h t © 1 9 9 8 - 2 0 0 9 C a m p b e l l S c i e n t i f i c , I n c .
Warranty and Assistance The SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products.
SC532A Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. Function ................................................................................... 1 2. Physical Description............................................................ 1 3. Specifications ........................................................................ 2 4. Hardware Connections ................................
This is a blank page.
SC532A 9-Pin Peripheral to 9-Pin RS232 Interface 1. Function The SC532A Peripheral Interface connects an IBM® PC compatible computer, with appropriate software, to certain Campbell Scientific datalogger peripherals including phone modems (COM200, COM210, COM220), storage modules (SM4M/16M, SM192/716), MD9 multi-drop interface, and Seimac SCD/Argos satellite transmitter. Like the SC532, the SC532A supplies 5 VDC on the PERIPHERAL connector (pin 1) to power 5V peripherals like the SM16M.
SC532A 9-Pin Peripheral to 9-Pin RS232 Interface 3. Specifications 2 Input voltage (to POWER jack) A) 5 Volt Peripherals require 6 − 17 VDC B) 12 Volt Peripherals require 12 − 17 VDC Barrel connector: inner bore (+), outer sleeve (−) (factory 120 V AC adapter supplies 12 VDC unregulated @ 1A) Output voltages +5 VDC ± 0.
SC532A 9-Pin Peripheral to 9-Pin RS232 Interface 9227 SN: Logan, UT SM4M PERIPHERAL MADE IN USA SC12 PC Logan, Utah SOLID STATE STORAGE MODULE SC532A RS232 to CS I/O MADE IN USA SN: POWER 9-Pin Cable FIGURE 2. Connection Block Diagram (9-pin cable, side power jack) FIGURE 3. DC Cable for 12 VDC Datalogger Connection 4. Hardware Connections Figure 2 shows the connection from a Campbell Scientific peripheral to a PC’s 9-pin RS232 COM port via SC532A and data cables. 5.
SC532A 9-Pin Peripheral to 9-Pin RS232 Interface 6. Portable Battery Power The 14020 and 14291 field cables are available for remote sites lacking 120 VAC. The 14020 field cable is equipped with a DB9 for connection to the datalogger’s CS I/O port. The 14291 cable terminates in two wires for attachment to the 12 V and power ground terminals of the datalogger or 12 Vdc power supply.
SC532A 9-Pin Peripheral to 9-Pin RS232 Interface TABLE 1. SC532A Power Supply Connector Barrel Connector Polarity and Size Inner Conductor (bore) Outer Conductor (sleeve) (+) 6 to 17 VDC (see Section 2) (−) GND O.D is 5.5mm (0.216 in.) I.D. is 2.5mm (0.098 in.) Sleeve length = 11.5mm (0.453 in.) or more TABLE 2.
SC532A 9-Pin Peripheral to 9-Pin RS232 Interface This is a blank page.
Appendix A. Pin Description The SC532A 9-pin female port is configured as Data Communications Equipment (DCE) for direct cable connection to Data Terminal Equipment (DTE) such as an IBM-PC serial port. The pin descriptions of the SC532A PC and PERIPHERAL connectors are listed in the following table. TABLE A-1.
Appendix A. Pin Description TABLE A-2. DTE 25 Pin Configuration PIN= ABR I = O = 25-pin number = Abbreviation for the function name Signal Into the computer Signal Out of the computer PIN ABR I/O 1 2 TX O 3 RX I 4 RTS O 20 DTR O 22 RING I 7 SG Function Frame Ground. Transmit Data: Characters are transmitted from the computer on this line. Receive Data: Characters transmitted by a peripheral are received on this line.
Appendix B.
This is a blank page.
Appendix C.
This is a blank page.
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za • cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444 Thuringowa Central QLD 4812 AUSTRALIA www.campbellsci.com.au • info@campbellsci.com.au Campbell Scientific do Brazil Ltda.