SC32B Optically Isolated RS-232 Interface Revision: 11/13 C o p y r i g h t © 1 9 8 7 - 2 0 1 3 C a m p b e l l S c i e n t i f i c , I n c .
Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless otherwise specified in the corresponding Campbell pricelist or product manual. Products not manufactured, but that are re-sold by Campbell, are warranted only to the limits extended by the original manufacturer.
Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 227-9000.
Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to specific sections. 1. Function.......................................................................1 2. Specifications .............................................................2 3. Connector Descriptions .............................................2 3.1 3.2 RS-232 ...............................................................................................
SC32B Optically Isolated RS-232 Interface 1. Function FIGURE 1-1. SC32B Optically Isolated RS-232 Interface The SC32B interfaces an RS-232 peripheral, commonly a computer or terminal, to the CS I/O port of a Campbell Scientific datalogger. The SC32B has the same functions as the SC32A. Functions include: 1. Converting datalogger logic levels to RS-232 logic levels. 2. Optically isolating the datalogger and the RS-232 peripheral.
SC32B Optically Isolated RS-232 Interface 2. 3. Specifications Operating Temperature: –25° to +50°C (typical) Power: Powered by datalogger; see Section 4, Operation Ports: 9 pin female RS-232 configured as DCE. 9 pin male CS I/O Baud Rate: 1200 bps to 115.2 kbps; see Section 4, Operation Size: 4.1 x 2.3 x 7.6 cm (1.6 x 0.9 x 3 in) Weight: 45.4 g (1.6 oz) Connector Descriptions TABLE 3-1.
SC32B Optically Isolated RS-232 Interface 4. Operation Power for the SC32B datalogger section comes from the 5 V supply on pin 1 of the datalogger CS I/O. Communication logic levels to and from the datalogger are referenced to this voltage, ranging from 0 to slightly less than 5 V. Power for the RS-232 section is isolated from the datalogger 5 V supply via a transformer/isolator. An on-board DC to DC converter supplies the negative voltage required for RS-232 signals.
SC32B Optically Isolated RS-232 Interface 4
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za • cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 8108 Garbutt Post Shop QLD 4814 AUSTRALIA www.campbellsci.com.au • info@campbellsci.com.au Campbell Scientific do Brasil Ltda. (CSB) Rua Apinagés, nbr.