Instruction Manual

Appendix L. RF401/RF411 Average Current Drain Calculations
The base RF401/RF411’s total average current (It) can be calculated over an
interval (T) as follows:
It = Is + Ih + Iq + Ir + Ii
Is = {table value}
REMOTE
The average current drain of a remote RF401/RF411 being collected on
schedule has 4 contributors:
1) The STANDBY AVG RECEIVE CURRENT Is
2) The average transmit current from data transmission Id
3) The average receive current of data request receptions Ir
4) The average receive current from “time of inactivity to sleepIi
The remote RF401/RF411’s total average current (It) can be calculated over an
interval (T) as follows:
It = Is + Id + Ir + Ii
Is = {table mA value}