Instruction Manual

Appendix L. RF401/RF411 Average
Current Drain Calculations
For remote sites with tight power budgets due to solar or battery power
supplies, the following will help determine average current consumption. The
RF401/RF411’s average current drain is based on:
Standby mode of RF401/RF411
Data collection interval
Number of data points collected
“Time of inactivity to sleep” selection
STANDBY MODES
TABLE L-1. Advanced Setup Menu
STANDBY
MODE
STANDBY
AVG RECEIVE
CURRENT
(Is)
DEFAULT
TIME OF INACTIVITY
TO SLEEP
(sec)
“LONG
HEADER”
LENGTH
(L)
0
1
< 24 mA ---- 0 ms
700 ms
3
2
< 4 mA 5
4
3
< 2 mA 5 1200 ms
5 < 1 mA 5 2200 ms
6 < 0.6 mA 5 4200 ms
7
4
< 0.4 mA 5 8200 ms
1
Standard Setup menu selection 1
2
Standard Setup menu selection 2
3
Standard Setup menu selection 3
4
Standard Setup menu selection 4
CALCULATIONS
BASE
The average current drain of a base RF401/RF411 configured for scheduled
collections has 5 contributors:
1) The STANDBY AVG RECEIVE CURRENT Is
2) The average transmit current of LONG HEADER Ih
3) The average transmit current of data request transmissions Iq
4) The average receive current of data receptions Ir
5) The average receive current of “time of inactivity to sleep” Ii
L-1