CR850.
Description: The current state of scheduled collection for the datalogger. The
following values are defined:
1. Normal – The normal collection schedule is active
2. Primary – The primary retry schedule is active
3. Secondary – The secondary retry schedule is active
4. Schedule Off – The collection schedule is disabled
5. Comm Disabled – Communication for this device, one of its parents,
or for the entire network is disabled
6. Invalid Table Defs – Collection for this station is disabled until the
table definitions are refreshed
7. Network Paused – Automated operations are paused for the network
8. Unreachable – The device cannot be reached through the network
A.2.15 Values in Last Collection
Column Name: “Vals in Last Collect”
Column Definition Description: “Vals Last Coll”
Type: uint4
Applies To: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X, CR10T,
CR10X-TD, CR510-TD, CR23X-TD, CR9000, CR5000, CR10X-PB, CR510-
PB, CR23X-TP, CR205, CR210, CR215, CR1000, CR3000, CR800, and
CR850.
Description: The number of scalar values that have been collected from the
datalogger since the last poll began
A.2.16 Values to Collect
Column Name: “Values to Collect”
Column Definition Description: “Vals to Coll”
Type: uint4
Applies To: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X, CR10T,
CR10X-TD, CR510-TD, CR23X-TD, CR9000, CR5000, CR10X-PB, CR510-
PB, CR23X-TP, CR205, CR210, CR215, CR1000, CR3000, CR800, and
CR850.
Description: The number of scalar values expected in the current or last poll.
A.2.17 Values in Holes
Column Name: “Values in Holes”
Column Definition Description: “Holes”
Type: uint4