User guide
EasyAG
®
Soil Water Content Profile Probes
3: Z=F x 10^n (P30)
1: -1000 F
2: 0 n, Exponent of 10
3: 17 -- Z Loc [ ES1_VIC_1 ]
4: End (P95)
;Measure water content scaled frequencies (SF)
5: Beginning of Loop (P87)
1: 0 Delay
2: 5 Loop Count
;See Appendix D for other SDI-12 commands
6: SDI-12 Recorder (P105)
1: 0 SDI-12 Address
2: 0 Start Measurement (aM0!)
3: 7 Port
4: 1 Loc [ ES1_SF_1 ]
5: 1.0 Mult
6: 0 Offset
7: If (X<=>F) (P89)
1: 1 X Loc [ ES1_SF_1 ]
2: 2 <>
3: 0 F
4: 31 Exit Loop if True
8: End (P95)
;Measure salinity volumetric ion content (VIC)
9: Beginning of Loop (P87)
1: 0 Delay
2: 5 Loop Count
10: SDI-12 Recorder (P105)
1: 0 SDI-12 Address
2: 2 Start Measurement (aM2!)
3: 7 Port
4: 17 Loc [ ES1_VIC_1 ]
5: 1.0 Mult
6: 0 Offset
11: If (X<=>F) (P89)
1: 17 X Loc [ ES1_VIC_1 ]
2: 2 <>
3: 0 F
4: 31 Exit Loop if True
12: End (P95)