User guide
EasyAG
®
Soil Water Content Profile Probes
Sample CR10X Program
Shaded portions of program can be omitted if TriSCAN sensors are not used.
;CR10X Datalogger
;Program Author: Campbell Scientific, Inc.
;Date: 04-12-06
;Description: Program measures 1 EnviroSMART / TriSCAN probe with 8 sensors or 1 EasyAG
; TriSCAN probe with 4 sensors. -1000 is loaded as the "measurement" for
; non-existant sensors. Program measures scaled frequencies, calculates
; water contents, and stores scaled frequencies, water contents, and
; volumetric ion contents separately. Scaled frequencies are stored with an
; "array identifier" leading 8 data values per record followed by 8 VIC per
; record, with the record ending with zero rain and irrigation values for
; compatibility with DBLOAD & Irrimax software.
;Assumptions: EnviroSMART or EasyAG probe SDI-12 interface is configured to output
; scaled frequencies
;Wiring: EnviroSMART / EasyAG 12 Volts (Pin 1)--------- CR10X 12 V
; EnviroSMART / EasyAG Ground (Pin 2)-------- CR10X Ground
; EnviroSMART / EasyAG Signal (Pin 3) --------- C7
; Rain Gage Pulse Out -------------------------------- CR10X P2
; Rain Gage Ground ----------------------------------- CR10X Ground
;{CR10X}
;
*Table 1 Program
01: 30 Execution Interval (seconds)
;Load Scaled Frequency to Water Content Co-effecients
a = .1957
b = .404
c = .02852
;Preload missing sensor error
1: Beginning of Loop (P87)
1: 0 Delay
2: 8 Loop Count
2: Z=F x 10^n (P30)
1: -1000 F
2: 0 n, Exponent of 10
3: 1 -- Z Loc [ ES1_SF_1 ]
9