Owner's manual

CS125 Present Weather Sensor
34
Consult the ‘calibration’ section of this manual for information on how to
calibrate the CS125 present weather sensor.
Once a calibration is finished changes are immediate, but factory
calibrations can be restored if needed using Option `(2)’ in the
calibration menu. The disk constants however remain as the last
disk used.
Option (4) gives the systems information menu containing useful information such
as temperature and system alarms.
Menu 4: The system information menu
If either of the dirty window alarms are set it is recommended you follow the
cleaning section of this manual (Section 18).
If there is a flash error or signature error it is recommended that you contact
Campbell Scientific.
NOTE
CS125 INFORMATION - MENU 4
ID 0
S/N 1003
OS version: 007646v1
Alarm Value
- Last visibility reading: - 3258M
- Overall system status: 0 No faults
- Emitter dirty window alarm: 0 0%
- Emitter internal temperature: 0 38.4
- Detector dirty window alarm: 0 0%
- Detector internal temperature: 0 31.0
- Detector DC light saturation: 0 -
- Hood heater temperature: 0 25.6
- CS125 Calibrator Serial No: - 1000
- CS125 Calibrator Constant: - 30.5
- Calibration value Fac offset: - -0.026
- Calibration value Fac scale: - 0.02682
- Calibration value Cal offset: - -0.026
- Calibration value Cal scale: - 0.02682
- Signature fault: 0 -
- Flash write errors: 0 0
- Flash read errors: 0 0
- Supply voltage: <7.0V 11.3V
- Aux supply voltages: +5V=5.0 -5V=-5.1
+6V=5.9
- External temperature: 0 26.4
- Present weather mode enabled
(8) Get debug
(9) Refresh
(0) Return to main menu
->