INSTRUCTION MANUAL CR10XTCR Thermocouple Reference Revision: 1/03 C o p y r i g h t ( c ) 1 9 9 5 - 2 0 0 3 C a m p b e l l S c i e n t i f i c , I n c .
Warranty and Assistance The CR10XTCR THERMOCOUPLE REFERENCE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products.
CR10XTCR Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. General ........................................................................1 1.1 Specifications............................................................................................1 2. Accuracy — Temperature Sensor .............................1 3. Installation and Wiring ..........................................
This is a blank page.
CR10XTCR Thermocouple Reference 1. General The Model CR10XTCR Probe contains a thermistor for measuring temperature and is used as a reference temperature for thermocouples measured with the CR10X. It is installed between the two terminal stripes in the wiring panel. After all the thermocouples are wired, the wiring panel cover is installed to minimize temperature gradients on the terminal strip. 1.
CR10XTCR Thermocouple Reference FIGURE 1. Error Produced by Polynomial Fit to Published Values 3. Installation and Wiring The wiring diagram for the CR10XTCR is shown in Figure 1. The probe requires a single-ended analog input channel and an excitation channel. After the CR10XTCR and thermocouple are connected to the datalogger, install the wiring panel cover (Figure 2 and 3). Switched Excitation; Black (E3) Analog Ground; Clear (AG) XTCR CR10 403 3 LT#34 Single-Ended Input; Red (1H) FIGURE 2.
CR10XTCR Thermocouple Reference , N A G O L H A T U E S EF D G 8 H 7 4 G L 0 1 H 9 5 G A E S EF D L G 2 H 1 1 L 2 G 1 A 1 6 L 1 H G G A H T D R N A U E O R C 3 E G A G A 4 H 3 2 G L G 6 H 5 3 G A L G G A G G L R T C V V 2 1 12 W W S S G 3 E G A G A G G H V 2 1 ER G W O P IN L H X 0 1 R C G A L G A C S 0 I/ M L E N A P G IN USA IR E IN W AD H V 2 M 1 D 3 S E G A L V 2 1 G . IN NO IR L W E N A P FIGURE 3.
CR10XTCR Thermocouple Reference EXAMPLE 1. Sample CR10X Instructions 01: Temp 107 Probe (P11) 01: 1 Rep 02: 1 IN Chan 03: 3 Excite all reps w/EXchan 3 04: 15* Loc [:Ref_Temp] 05: 1 Mult 06: 0 Offset * Proper entries will vary with program and input location. 5. Instruction 11 Details Understanding the details in this section are not necessary for general operation of the CR10XTCR with Campbell Scientific's dataloggers.
CR10XTCR Thermocouple Reference TABLE 3. Temperature, Resistance, and Datalogger Output Temperature °C -40.00 -38.00 -36.00 -34.00 -32.00 -30.00 -28.00 -26.00 -24.00 -22.00 -20.00 -18.00 -16.00 -14.00 -12.00 -10.00 -8.00 -6.00 -4.00 -2.00 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 30.00 32.00 34.00 36.00 38.00 40.00 42.00 44.00 46.00 48.00 50.00 52.00 54.00 56.00 58.00 60.
CR10XTCR Thermocouple Reference TABLE 4. Polynomial Coefficients Coefficient Value C0 C1 C2 C3 C4 C5 -53.4601 90.807 -83.257 52.283 -16.723 2.211 6. Electrically Noisy Environments AC power lines can be the source of electrical noise.
This is a blank page.
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za sales@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444 Thuringowa Central QLD 4812 AUSTRALIA www.campbellsci.com.au info@campbellsci.com.au Campbell Scientific do Brazil Ltda.