User guide

52202 Electrically Heated Rain and Snow Gage
5.1.3 CR10X Example Program
;{CR10X}
*Table 1 Program
01: 1.0000 Execution Interval (seconds)
1: Pulse (P3)
1: 1 Reps
2: 1 Pulse Channel 1
3: 2 Switch Closure, All Counts
4: 3 Loc [ Rain_mm ]
5: 0.1 Multiplier
6: 0 Offset
2: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
3: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 101 Array ID
4: Real Time (P77)
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
5: Totalize (P72)
1: 1 Reps
2: 3 Loc [ Rain_mm ]
*Table 2 Program
01: 0 Execution Interval (seconds)
*Table 3 Subroutines
End Program
5.2 Control Port Example
The following example programs use a control port to read the output from the
precipitation gage. The CR1000 example will also work with the CR800,
CR850, and CR3000. The CR10X program will also work with the CR500,
CR510, or CR23X.