223 Delmhorst Cylindrical Soil Moisture Block
7.2.5.2 Example CR10(X) Program
CR10(X)
Multiplexer
FIGURE 7-4. Wiring for CR10(X) example
*Table 1 Program
01: 60.0000 Execution Interval (seconds)
01: Do (P86) ;Enable multiplexer
1: 41 Set Port 1 High
02: Beginning of Loop (P87) ;Start of measurement loop
1: 0 Delay
2: 16 Loop Count
03: Do (P86) ;Clock Multiplexer to next channel
1: 72 Pulse Port 2
04: Step Loop Index (P90) ;Step index by 2 each pass through loop
1: 2 Step
05: AC Half Bridge (P5) ;Measure the 2 connected 223 blocks
1: 2 Reps
2: 14 250 mV Fast Range
3: 1 SE Channel
4: 2 Excite all reps w/Exchan 2
5: 250 mV Excitation
6: 1-- Loc [ BlockR_1 ] ;-- >>> advance location by index
7: 1.0 Mult
8: 0.0 Offset
06: BR Transform Rf[X/(1–X)] (P59) ;Calculate resistance from Vs/Vx
1: 2 Reps
2: 1-- Loc [ BlockR_1 ]
3: 1 Multiplier (Rf)
07: End (P95)