User Manual
223 Delmhorst Cylindrical Soil Moisture Block 
7.  Operation 
The black outer jacket of the cable is Santoprene
® 
rubber. 
This compound was chosen for its resistance to 
temperature extremes, moisture, and UV degradation.  
However, this jacket will support combustion in air. It is 
rated as slow burning when tested according to U.L. 94 
H.B. and will pass FMVSS302. Local fire codes may 
preclude its use inside buildings. 
CAUTION 
7.1  Wiring 
The 223 is shown in FIGURE 7-1 and TABLE 7-1. The leads from the block 
electrodes are connected directly to the H and L inputs on the AM16/32-series, 
AM32, or AM416 multiplexer. The lead from the center electrode (white 
stripe or solid white) connects to H and the lead from the outer electrode 
(black) to L. A 1k resistor at the datalogger is used to complete the half bridge 
measurement. 
Black with
White Stripe
(or White) to H
Black
to L
FIGURE 7-1. 223 wiring 
TABLE 7-1. 223 Wiring 
Color Function Multiplexer 
Black w/ White Stripe or White  Excitation  H 
Black Signal Ground L 
8 