Manual
R.M. Young Wind Sentry
7: If (X<=>F) (P89)
1: 3 X Loc [ WindDir ]
2: 3 >=
3: 360 F
4: 30 Then Do
8: Z=F x 10^n (P30)
1: 0 F
2: 0 n, Exponent of 10
3: 3 Z Loc [ WindDir ]
9: End (P95)
10: If (X<=>F) (P89)
1: 3 X Loc [ WindDir ]
2: 4 <
3: 0 F
4: 3 Then Do
11: Z=F x 10^n (P30)
1: 0 F
2: 0 n, Exponent of 10
3: 3 Z Loc [ WindDir ]
12: End (P95)
13: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
14: Set Active Storage Area (P80)^15464
1: 1 Final Storage Area 1
2: 101 Array ID
15: Real Time (P77)^6687
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
16: Wind Vector (P69)^28601
1: 1 Reps
2: 0 Samples per Sub-Interval
3: 0 S, theta(1), sigma(theta(1)) with polar sensor
4: 2 Wind Speed/East Loc [ WS_ms ]
5: 3 Wind Direction/North Loc [ WindDir ]
5.5 Long Lead Lengths
When sensor lead length exceeds 100 feet, the settling time allowed for the
measurement of the vane should be increased to 20 milliseconds.
11