Measurement and Control Module Operators Manual

SECTION 3. INSTRUCTION SET BASICS
3-11
*D Mode errors indicate problems with saving
or loading a program. Only the error code is
displayed.
TABLE 3.10-1. Error Codes
Code Type Description
03 Editor program table full
04 Compile Intermediate Storage full
05 Compile Storage Area #2 not
allocated
08 Run Time CR10 reset by watchdog
timer
09 Run Time Insufficient Input Storage
11 Editor Attempt to allocate more
Input or Intermediate
Storage than is available
20 Compile SUBROUTINE encountered
before END of previous
subroutine
21 Compile END without IF, LOOP or
SUBROUTINE
22 Compile Missing END
23 Compile Nonexistent
SUBROUTINE
24 Compile ELSE in SUBROUTINE
without IF
25 Compile ELSE without IF
26 Compile EXIT LOOP without
LOOP
27 Compile IF CASE without BEGIN
CASE
30 Compile IF and/or LOOP nested
too deep
31 Run Time SUBROUTINES nested
too deep
40 Editor Instruction does not exist
41 Editor Incorrect execution
interval
60 Compile Inadequate Input Storage
for FFT
61 Compile Burst Measurement Scan
Rate too short
96 *D MODE Addressed device not
connected
97 *D MODE Data not received within
30 seconds
98 *D MODE Uncorrectable errors
detected
99 *D MODE Wrong file type or editor
error