Measurement and Control Module Operators Manual
B-1
APPENDIX B. CR10 PROM SIGNATURE AND OPTIONAL SOFTWARE
B.1 PROM SIGNATURE AND VERSION
The CR10 PROM signature is viewed by
entering the *B Mode and advancing to window
2 (Section 1.6). The version number is in
window 6 and the revision number in window 7.
The signatures of current standard PROMs are
listed in Table B-1. If the CR10 has a Library
Option PROM, the signature is listed on the
calibration sheet shipped with the datalogger.
The instructions for using the special features,
can be found in Appendix H.
TABLE B-1. CR10 PROM Signatures
PROM SIGNATURE PROM NUMBER REVISION NUMBER
DESCRIPTION *B, WINDOW 2 *B, WINDOW 6 WINDOW 7
OS10-0.1 51903 .10000 0001
OS10-1.1 55030 1.1000 0001
OS10-0.1-4K 19464 90.100 0000
TABLE B-2. CR10 Library Options
INST. NO. DESCRIPTION BYTES
Core files must be included 2578
13,14 Add R, S, & B Thermocouple Linearizations 456
15 Control Port Serial I/O 1111
23
1
Burst Measurement 1588
27,28
1
Period, Vibrating Wire Measurement 932
64 Paroscientific "T" Series Processing 169
101
1
SDM-INT8 549
102
1
SDM-SW8A 268
103,104
1
SDM-AO4, SDM-CD16 239
SDM Utilities 216
105,106
SDI12 Recorder/Sensor 1528
60 FFT 2297
62 Covariance/Correlation 796
81 Rainflow histogram 1159
97
1
Initiate telecommunications 880
98
1
Send Character 73
99 Satellite Interface 3143
64 Hz Pulse counters reset -3
*4 Parameter Entry Table 575
*D Add Tape up/down load 1196
1
These instructions are in OS10-0.1 and are described in the standard manual.
B.2 AVAILABLE PROMS / LIBRARY
OPTIONS
The set of instructions available in the CR10 is
determined by the PROM (Programmable Read
Only Memory that it is equipped with. If the
standard PROM, OS10-0.1, does not fit the
customer's application it is possible to create a
library option PROM with the instructions and
features desired, provided the memory capacity
of the PROM is not exceeded.
Library Option PROMS are assembled from a
base set of instructions plus selected functions
in Table B.2-1. Consult a Campbell Scientific
applications engineer for pricing and help in
configuring a library option.
B.3 DESCRIPTION OF LIBRARY OPTIONS
NOT IN STANDARD MANUAL
The following is a brief description of library
options not found in the standard manual. If the