User manual
11
Operating Instructions and Assembly Instructions 
Airless Paint Sprayers
CLEANUP FOR CHANGING PAINTS 
OR TEMPORARY STORAGE FOR 
MORE THAN ONE NIGHT
WEAR ALL NECESSARY 
SAFETY GEAR
NECESSARY TOOLS / MATERIALS:
• Pliers
• Rag
• Gloves
• Two (2) buckets
• At least one (1) gallon of cleaning 
fluid
• Cleaning brush
NOTE:  Do NOT disconnect any hoses.
NOTE:  Refer to coating manufacturer 
for recommended cleaning fluid.
1.  Turn prime/spray control to PRIME 
position.
2.  Turn power switch to ON.
  High pressure 
  hose may still be 
pressurized with prime/spray control 
in the PRIME position. With the gun 
pointed in a safe direction, pull the 
gun trigger to relieve any pressure in 
the hose.
3.  Turn pressure to HIGH (completely 
clockwise).
4.  Tilt unit back, lift suction assembly 
above fluid level in bucket.
  While holding suction assembly 
above paint level, allow pump to 
run until empty.
5.  Immediately place both suction 
assembly and bypass tube in a 
bucket containing enough cleaning 
fluid to cover suction bell by two 
inches. Allow pump to prime and 
begin circulating fluid.
6.  While fluid is circulating, soak rag 
in fluid and wipe exterior of suction 
assembly and bypass tube. Remove 
suction filter with pliers. Wipe 
inside of suction filter housing with 
rag removing excess paint buildup. 
Clean both sides of suction filter 
with rag and reinsert filter into 
suction filter housing.
NOTE: Do NOT allow fluid to circulate 
for more than 15 minutes.
Cleaning Pump
Turn Pressure to HIGH 
(completely clockwise)
3
4
Lift Suction Assembly above 
Paint Level in Bucket
www.chpower.com
Turn Prime/Spray 
Control to PRIME 
Position
1
6
Wipe Exterior of Suction 
Assembly and Bypass Tube
Suction Assembly and 
Bypass Tube in Bucket
of cleaning fluid
11
2
Turn power switch to ON 
(shown in the OFF position)
5