Instructions / Assembly
6
• Type 1 Connections
• Diameter - 12” / 31.1cm
• Height - 18.25” / 46cm
• 9.07 kg / 20 lb LPG capacity or 21.6 kg /
47.6 lb water capacity
• Must be provided with a listed overfilling
prevention device
The gas cylinder used must include a collar
to protect the cylinder valve. The cylinder
supply system must be arranged for vapor
withdrawal.
Follow the instructions stated on gas
cylinder tanks when filling or transporting
tanks. Failure to do so could result in
problems relating to overfilling, excessive
venting release of gas and to regulator
freezing. Never fill the cylinder more than 80
percent full.
CAUTION
In the connection process, the HVR side
of the connection will seal on the back
check in the valve, resulting in a slight
resistance. The connection requires about
one-half to three quarters additional turn
to complete connection. Any fuel supply
cylinder used must be constructed and
marked in accordance with specifications for
propane cylinders of the U.S. Department of
Transportation (DOT)CFR 49 or CAN/CSA
B339.
Do not allow dirt or foreign material to get
into or onto tank connection when it is not
attached to the fuel supply system. Use the
protective cap provided. Place dust cap on
cylinder valve outlet whenever the cylinder is
not in use. Only install the type of dust cap on
the cylinder valve outlet that is provided with
the cylinder valve. Other types of caps or plugs
may result in leakage of propane. Cylinders
must be filled before initial use. All handling,
transport, filling and storage of LP gas
cylinders must be in accordance with NFPA
58 Storage and Handling of Liquid Petroleum
Gasses, or CAN/CSA b149.2 Propane
Installation Code.
CAUTION
The gas pressure regulator provided with
this appliance must be used. This regulator
is set for an outlet pressure of 11” H20.
Replacement pressure regulators and hose
assemblies must be those specified by the
fire pit manufacturer. See rating sticker on
side of fire pit for regulator model number.
The regulator/hose assembly should be
handled carefully to prevent contamination
by foreign objects and dirt. The assembly
should be inspected before use and any dirt
or contamination should be wiped off. The
hose assembly must be replaced prior to the
appliance being used if there is any evidence
of excessive abrasion or wear, or if the hose
is damaged. In order to insure
proper operation, any replacement of the
regulator assembly must be with parts
authorized by manufacturer. Valve/pressure
regulators are factory set to the correct
operating pressures. No attempts should be
made to adjust these settings.
Cylinders must be suitably tied down during
transport. Do not place any other items on top
of cylinders at any time.
Cylinders are not to be exposed to excessive
temperatures or high heat. Refer to the
data plate for model identification. Units are
factory equipped for use on only one type of
fuel. These units cannot be, and should not
be used on other types of fuels. Doing so
can cause severe damage to the unit and the
installation area and the added risk of serious
injury. Any attempt to operate this product
on fuels for which it is not designed voids the
manufacturer’s warranty.
This unit is not to be utilized with a non-self-
contained LP-gas supply system.
WARNING
Appliance must be leak checked outdoors
in well-ventilated area, away from ignition
sources such as gas fired or electrical
appliances. During leak test, keep appliance
away from open flames or sparks.
LEAK TESTING
1. Turn all control knob(s) to OFF.