BIOMETRIC FINGERPRINT RECOGNITION EASY HOME / EASY MOBILE 1 2 3 4 5 6 7 8 * 0 9 User Manual
SAFETY INSTRUCTIONS 2 You have purchased a high quality hi-tech product. Please handle with care and caution. Warning Safety advise Never open the units. You may risk an electrical shock or to damage sensitive parts. Even if the system locks or unlocks your house or car, you will be held responsible for proper locking. In case of any defect, please power off the system and consult your local dealer or the manufacturer. Leaving your house or car, please make sure that it is properly locked.
TABLE OF CONTENTS 3 Thank you for purchasing an Easy Home / Easy Mobile System.
BASICS Technology 4 About biometrics. „Biometrics“ refers to all kind of methods for uniquely recognition of humans based on one or more specific physical or behavioural characteristics. The more unique those characteristics are, the more they are applicable for definite identification. The oldest of all biometric methods is the finger print identification, the so-called dactyloscopy (greek. dactylos „finger” and scopein „view”).
BASICS Applications 5 How to use the CAMOS systems. Easy Home Easy Home was developed for the use in the automotive industry. The approval regulations are much stronger than for domestic applications, particularly with regard to more intensive environmental impacts, such as sunlight, moisture or temperature fluctuations. Since our products meet those requirements, they are most suitable for domestic usage. To use the Easy Home you need to install an electromechanical door locking system.
FIRST STEPS Shipment 6 The components.
FIRST STEPS Key pad 7 How to use the key pad and how read the step by step guide. All component settings are prepared to work out of the box after installation. The major tasks after the installation are to set the master password and to enrol the fingerprints of the authorized persons. For more individual settings the control unit is equipped with a display and a key pad. On the following pages all expert functions will be explained step by step.
FIRST STEPS Menu structure 8 The menu structure and navigation. Handling To set up the system you need to navigate through the below menu structure. For this purpose you will use the keys , , and . For a better understanding, please imagine a virtual 2D-button: The basic functions are available after single login into the system menu. Some expert settings require exact knowledge about the functionality of the BIOLOCK components. Access to these functions will be granted by re-entering the PIN number.
FIRST STEPS Login 9 Login and access to system stettings and functions. The access to the main menu is protected by a personal identification number (PIN). Step by step guide Display Input The factory default PIN is „1234”. It is recommended to change the PIN immediately after first login. On the following pages all functions will be explained. To achieve a higher legibility, the login procedure will be shown in a short form: , ~ , CAMOS ~ , PIN please You are logged in.
FIRST STEPS New PIN 10 How to change the PIN. The default PIN is „1234”. It is highly recommended to change the PIN to a personal value. The PIN might consist of 4 up to 12 digits. The longer the PIN is, the more secure it is. Optimal protection is achieved with a minimum of 5 digits. Usually PINs should not show any relation to your personality, such as birthday, age, etc. The main unit of the BIOLOCK system will be installed inside.
FIRST STEPS Language 11 How to select another language. The default language for the display and the menu is English. With less effort you can select your favourite language. Step by step guide Display Input , Please follow the instructions on the right, rebooting the system is not necessary.
FIRST STEPS Enrol new 12 Register new fingerprints. Fingerprints will be stored as so-called “Templates” in the memory of the control unit. It is not possible to re-construct complete fingerprint images from the templates, but to compare two templates with each other. The memory is organized like a relational database, i.e. every fingerprint will be assigned to a unique storage index (ID) number. Every new fingerprint will be allocated to the next available ID.
FIRST STEPS Fingerprint Sensor Usage 13 How to use the fingerprint reader. 1. Open sensor cover. 2. Blue LED turns on. 3. Place finger smoothly and straight. 4. Close sensor cover. Hints For security reasons there is an integrated time-out after 3 seconds. For security reasons you will have only three attempts for fingerprint recognition. After that you have to close and open the cover again. If the sensor position is inconvenient for using your forefinger, we recommend to use your thumb. max.
USER MENU Verify ID 14 Verify existing fingerprint templates. After enrolment you might want to verify the fingerprint. Please enter the ID and let the system check your finger again. This function is helpful if the reader must be installed in a difficult position and in case you are not sure that placing the finger is convenient for you for a longer time. It will enable you to test several times without activating the door opening mechanism.
USER MENU Delete ID 15 How to delete one fingerprint template. A single fingerprint template can be deleted by its storage number, its ID. Step by step guide Display Vice versa you cannot delete a fingerprint without its ID. If you want to use the system with a high volatile user group, it is recommended to keep a separate list with user to ID reference. Otherwise the database must be erased completely and the remaining persons must be registered again.
USER MENU Delete all 16 How to delete all stored fingerprint templates. You can delete all stored templates in one step. Step by step guide Display Please use this functionality carefully, the remaining persons must be registered again! Input , , ∂User Menu ∑Delete all Delete all? Please wait...
SETUP Sleep timer 17 How to set the sleep timer. You can log off the system menu whenever your current task is completed by pressing key. the Step by step guide Display , In case that you cannot finish your job or if you get distracted, the system will log off after a certain period for security reasons. This period for the sleep mode timer can be adjusted from 5 to 99 seconds.
SETUP Alarm 18 How to use the alarm function. The control unit provides a sensor input that operates as normally closed (NC) door switch. This means, the quiescent current will be interrupted in case of opening the door. For example you can connect a dry reed contact (NC). The system can react with various activities. The alarm function is deactivated by default and can be activated as explained in the right side.
SETUP Door sensor 19 How to activate the door sensor. The controller is equipped with a sensor input that is prepared for a NC (normally closed) door contact, i.e. a dry reed contact. Step by step guide Display , The system can detect that the door is open, and react accordingly. ∂User Menu The door contact is disabled by default. You may enable as explained herein. ∂Setup 1 2 PIN please When enabled and the door is open, the outputs will remain active until the door will be closed again.
SETUP Device ID 20 How to set the system ID. Due to security reasons reader and controller must be paired. In case of exchanging the reader, the system will not work. The units are paired by factory settings. Under normal conditions it is not necessary to change the ID. Anyhow, if you like to change the system ID, you may select a system ID from 1 to 15. You need to change the ID via DIP switch on the back side of the reader and the settings in the system menu.
CONNECTORS Out 1 21 How to operate output 1. The controller offers two separately configurable outputs. Step by step guide Display Each output can be operated either as switchable DC supplier or as potential-free relay contact. The mode selector (DIP switch) is located on the back side of the control unit. The meaning of the DIP switch setting is explained on the next page. You will find the specification of the outputs in chapter Technical Data/Specification on page 30.
CONNECTORS Out 2 22 How to operate output 2. Output 2 works similar to output 1. You will find a detailed explanation on the previous page. The factory setting for output 2 is DC mode and operating current in normal mode. Without any modification, you can connect a door magnet to the output 2. You can configure the port as explained on the right.
CONNECTORS Out mode 23 How to connect external devices to the outputs. The control box offers two outputs to be connected with door openers, optical or acoustical signal indicators. Also they can be connected to sensor inputs of alarm systems. Both outputs can be operated synchronously or independently from each other. The system can distinguish between short (< 3 sec.) and long (≥ 3 sec.) finger contact. For your support, the reader will signal by pulse sound.
CONNECTORS Relay time 24 Setting the relay time. In case of positive fingerprint recognition, the outputs will be operated as per settings. (please see previous pages) Step by step guide Display The duration of the output activity is triggered by the relay time value. The period may be set from 1 to 99 seconds. Please read the manual of the external device to find out optimal settings.
SYSTEMCHECK Check door 25 Quick test for output 1. The system is configured to work with a standard electric strike by factory default. Step by step guide Display Usually the strike will be connected to output 1, since this port can be operated by touch sensor on the controller. (compare installation guide) To check the port settings and the wiring after installation, you may use the quick test function. ∂User Menu ∂Systemcheck ∑Check door Check output 1...
SYSTEMCHECK Check all 26 Complete system connector test. This function will start a complete connector test and will check the fingerprint reader. Step by step guide Display If the system ID is displayed correctly, the reader is well connected. Otherwise please check the link. Afterwards the outputs 1 and 2 will be switched 3 times. At least the input will be checked. To complete the test, please operate the door contact at least one time.
FW-UPDATE Controller 27 Updating the controller firmware. The update functionality is meant for specialist usage only and to update new language files. A consecutive update is not necessary and updates will be provided only in case of complex matters. The access via PC/USB to the biometric system requires a special software. Otherwise it is not possible to get access.
FW-UPDATE Set default 28 How to return to default values. If some of your settings do not have the expected effect or if you lost the overview, you may re-set the system to default values. Step by step guide Display , Stored fingerprint templates will not be deleted. If you sell the system or will not use it any longer, please do not forget to delete all fingerprints for security reasons.
FW-INFO Controller and Reader 29 How to retrieve controller (1) and reader (2) firmware version. In case of trouble shooting, please check all connectors and wiring first. Step by step guide Display If it is still necessary to achieve technical help of our service team, check and write down the software versions before calling. This might help to fix the troubles quickly. The version numbers of controller and reader do not match. This is no mistake.
TECHNICAL DATA Specifications 30 Specifications and connector limits. Fingerprint reader BMR-207 Sensor technology Active capacitive hybrid Sensor type Flatbed sensor False Rejection Rate (FRR) ≤ 0.01 % False Acceptance Rate (FAR) ≤ 0.001 % Reader speed 0.5 s ESD protection 30 kV Wear protection (cycles) > 1.000.000 Dust and moisture protection IP 54 Internal communication RS-485 (reader-controller), max.
TECHNICAL DATA Trouble shooting 31 How to solve malfunctions. Strange signal sounds Strange display behaviour Errors in fingerprint recognition Malfunction in using the system menu Red controller LED is on. Please check the power supply. Most of the malfunctions are caused by weak power or power overload. Optimal power supply is 12 V DC / 2 A. Please check the link between reader and controller, this is a combined data and power supply line. Alarm sound and/or blue controller LED is active.