User guide


User
Guide
Page 113
Event Handling
Physical Configuration for Alarm
The alarm input and ground of  RX video recording server need to connect to
various kinds of sensors which are commonly installed at entrance or special part of the
surveillance area.
Alarm Setup Procedure
1.
Press “Menu button, select [SETUP] option
and press “Enter button to enter [SETUP]
sub menu. Select [EVENT HANDLER] option
and press “Enter button.
2.
Select [ALARM] option and press “Enter
button to show the alarm selection menu. Select
appropriate alarm and press “Enter button
to enter the alarm setting menu.
3.
Select [ENABLED] option and use “Left
or Right button to enable (i.e. set the
value to [YES]) alarm.
4.
Select [SENSOR TYPE] option and use “Left
or Right button to choose sensor
type according to the configuration of
 RX alarm sensor control circuit type.
SETUP MENU
VIDEO . . .
RECORDING . . .
SWITCHES . . .
DATE / TIME . . .
CONNECTION . . .
EVENT HANDLER . . .
TRANSMITTER . . .
PASSWORD . . .
USER ACCOUNT . . .
RX-SE . . .
SETTING IMPORT/EXPORT . . .
RESTORE FACTORY SETTING ENTER
EVENT HANDLER
ARM / DISARM . . .
SECURITY SWITCH . . .
ALARM . . .
MOTION . . .
VIDEO LOSS . . .
SYSTEM TAMPER . . .
POWER FAILURE . . .
DISK USAGE . . .
OVERHEAT . . .
HDD AVAILABLE
ALARM 1 SETTING
ENABLED YES
SENSOR NAME ALARM 1
SENSOR TYPE NO
SENSOR TAMPER TYPE NONE
ZONE TYPE NORMAL
ENTRY DELAY 0 SEC
EXIT DELAY 0 SEC
ACTION
ALARM 1 SETTING
ENABLED YES
SENSOR NAME ALARM 1
SENSOR TYPE NC
SENSOR TAMPER TYPE NONE
ZONE TYPE NORMAL
ENTRY DELAY 0 SEC
EXIT DELAY 0 SEC
ACTION