Specifications

Page 25
Appendices
Front of CameraMan Camera
Appendix A: Troubleshooting
Problem: The CameraMan autoTRACK Camera will not follow the Tracking
Ring Package.
Solution: 1. Is the POWER LED on the CameraMan’s front panel illuminated?
If it is illuminated, proceed to step #2.
If it is not illuminated, make sure the Main Docking Station is
plugged in and its POWER switch located on the front panel is
moved to the ON position. The POWER LED on the front of the
Main Docking Station should be illuminated.
2. Is the TRACKING UNIT STATUS LED on the camera’s front panel
illuminated?
If it is ON, proceed to step #3.
If it is OFF, make sure the Tracking Ring Power Pack is powered ON.
If it is still OFF, check the Battery LOW LED on the top of the
Tracking Ring Power Pack. If the Battery LOW LED is
illuminated, then the battery is low and needs to be recharged.
If both the ON LED and the LOW LED on the top of the Power
Pack are not illuminated, then the battery may be completely
discharged and needs to be fully recharged.
If the battery is fully charged and the TRACKING UNIT STATUS
LED is still OFF, then verify that the RF CHANNEL switch on the
back of the Main Docking Station matches the position of the RF
CHANNEL switch on the back of the Tracking Ring Power Pack.
3. Is the autoTRACK LED on the camera’s display panel illuminated or
flashing?
If it is ON, proceed to step #4.
If it is OFF, use the Tracking System Keypad to select one of the
four autoTRACK View buttons.
4. If the POWER and the TRACKING UNIT STATUS LEDs are
illuminated, and the autoTRACK LED is blinking,
Check to make sure that the Tracking Ring Sensors are
attached properly and are not covered by hair or clothing.
Be sure that you are standing in the field-of-view of the camera.
If you have any problems with your CameraMan Presenter Camera System, please try to resolve them using the following
information. If you still have questions, then please contact your authorized reseller, or call Grass Valley direct at (904) 596-3500.
Step 1:
Is POWER LED
ON?
Step 2:
Is TRACKING
UNIT STATUS
LED ON?
Step 3:
Is autoTRACK LED
FLASHING?
Power ON?
Battery Charged?
RF CHANNEL
RF Switch set to
the same
channel?
Only one (1) Presenter System may be operated in a Line-of-Sight room/area at a given time.