Specifications
Page 24
CameraMan
®
1-CCD Presenter Camera System Installation and Operations Manual
Setting Up Gen Lock with Your Tracking System Keypad
Gen Lock Setup (without the overlay card)
The following procedure will enable you to adjust Gen Lock settings without the Gen Lock
Setup overlay card.
1. Press and hold down the Setup and Image Brighten buttons. After 2-3 seconds, you
will hear a beep.
2. Release the Setup and Image Brighten buttons. The Gen Lock Setup menu
appears.
To reset the menu items to the default values, press the autoFOCUS button.
3. Press the up and down PAN/TILT arrows to move the arrow on-screen and to select
the item you want to change.
4. Press the left and right PAN/TILT arrows to change the value for the following
items:
Menu Item
Values
MODE AUTO or INT (internal)
H-PHASE -99 to +99
SC-PHASE 0 or 180
SCFINE -99 to +99
5. To save your changes, press the autoIMAGE button.
6. Press and hold SETUP and the top IMAGE (brighten) button to exit.
The SC-PHASE is set using Dip Switch Bank “A” number 2 on the
camera base unit: DOWN = 0° and UP = 180°.