DMX
ITALIANO
POLSKI
ESPAÑOL
FRANCAIS
DEUTSCHENGLISH
CABLING THE CONNECTION TERMINAL
Important Safety Instructions:
Opening the spotlight and connecting cables to the terminal connector requires specialist knowledge and may only be carried
out by specially trained personnel! If you are not suitably qualified, do not attempt to open the spotlight and attach cable
yourself. Refer instead to a qualified professional.
The manufacturer shall not be liable for any damage to property or personal injury caused by improper handling.
The terminal connector may be used only as an alternative to the input and output sockets on the spotlight.
This applies to the DMX connections as well as the mains connections.
Fully disconnect the spotlight from the mains before opening it
(remove the mains cable from the spotlight)!
The cables must not be used to suspend the spotlight from a ceiling or similar.
The cables must only be used for mains and signal supply.
To suspend the spotlight, only the securing lug and an appropriate suitable security cable should be used.
Loosen the three cross head screws
A
on the terminal cover with a suitable tool and remove the cover from the spotlight housing.
The terminal cover has 3 cable bushings. Feed a suitable 3-core mains cable (zero potential!) through the larger cable bushing
B
and 1
(only DMX IN) or 2 DMX cables (DMX IN and OUT) through the smaller cable bushing(s)
C
.
A
A A
B
C C
Loosen the 2 securing screws of the terminal block with the power supply cables and remove it from the corresponding terminal (terminal
block connector
D
). Use suitable ferrules for the stripped cable ends and attach the 3-core mains cable to the corresponding contacts
of the accompanying terminal block for the power supply. Observe the correct allocation (see diagram below, L=Live, G=Ground/Earth,
N=Neutral). Attach the terminal block to the corresponding terminal block connector
D
and secure it with screws.
POWER IN DMX OUTDMX IN
L G N
G - + G - +
DMX1 DMX2
D
E F
Remove the terminal blocks for DMX IN (
E
/ DMX1) and DMX OUT (
F
/ DMX2) from the terminal block connector and connect the 3
leads from the DMX cable to the corresponding contacts on the terminal blocks (G = Ground/Earth, - = Negative, + = Positive). Attach the
terminal blocks to the corresponding terminal block connectors, then seal the connection terminal with the terminal cover and secure it with
the previously loosened screws. Protect the terminal connector from mechanical stress by ensuring that the clamping nuts for the cable
bushings are securely tightened.