Operation Manual

Table Of Contents
13
DMX
DEUTSCHFRANCAIS
ESPAÑOL
ENGLISH
ITALIANO POLSKI
Temperature = Displays temperature of
LED unit
LED xxx°C / xxx°F
C/F Unit Celsius (= display in degrees Celsius)
Unit Fahrenheit (= display in degrees Fahrenheit)
Operation Hours = Displays operating time Operation Hours
xxxx:xxh
Displays total operating time in hours and minutes
MANUAL LOCKING FUNCTION
In addition to the ability to automatically protect the spotlight from accidental and unauthorised operation (see „Settings“ –
„Auto Lock“), the controls can also be locked manually. Press and hold the UP and DOWN controls simultaneously for approximately 5
seconds. „LOCKED“ is now displayed and it is no longer possible to change the spotlight’s settings via the controls. After approx. eight mi-
nutes, the current operating mode is displayed again. To unlock, press and hold the UP and DOWN controls simultaneously for approximately
5 seconds. The display will show the previously displayed information.
DIFFUSERS
Two diffusers are supplied with the spotlight, each with a different beam angle (32°, 45°).
The beam angle of the spotlight can be set at 22° (without diffuser), 32°, or 45°. Loosen the four cross-head screws
A
on the retaining
ring on the front of the spotlight with a suitable tool and remove the retaining ring from the spotlight. Use a small flat-bladed screwdriver to
remove the diffuser from the retaining ring. Insert the required diffuser in the retaining ring and then secure the ring to the spotlight with the
previously loosened screws.
A
A
A
A