Information

MATERIAL SAFETY DATA SHEET
According the European directive 2001/58/CE Date : 12.10.2010
Rev : PB-ST-1005
Page# - 4 -
and local regulations. Appropriate disposal
technologies
include incineration and landfill.
8. Exposure controls/Personal protection
Exposition/ Technical measures Atmospheric vapor concentrations must be
minimized by adequate ventilation.
Protection of hands, eyes and skin: To protect hands, eyes and skin, the use of
appropriate chemical resistant glovers, safety glasses and suitable protective clothing is
strictly recommended.
9. Physical and chemical propertied
Physical state Liquid Solubility in water soluble
Color Any colors Vapor pressure no applicable
Odor COOL COLOGNE Smell Explosion limit not applicable
pH value not determined Oxidizing properties not applicable
Specific gravity 0.990-1.040 (at 25oC) Flashpoint not determined
Refractive index 1.480-1.515 (at 20oC) Auto flammability not determined
Solubility in ethanol soluble Partition coefficient not determined
Melting Point not applicable Boiling Point not determined
Freezing Point not determined
10. Stability and Reactivity
Good stability at standard temperature. Avoid temperatures above or close to the flash point.
Never heat sealed containers. This product presents no significant reactivity hazard, by itself or in
contact water.
Reactivity: Avoid contact with acids. Alkali or strong oxidizing agents.
Hazardous decomposition products: carbon monoxide and unidentified organic compounds my
be formed during combustion.
11. Toxicological information
The product is multi component mixture for which no toxicological date exists.
This preparation is classified XI, N R38-43.
12. Ecological information
In general, no ecological date is available for preparations.
Precautions Avoid disposing into drainage systems and in the environment.
13.Disposable considerations
Don not dispose of into environment or into sewerage. If recycling is not possible, the
product and its container have to be disposed of in accordance with your local legislation
and regulations. Alkaline batteries, containing corrosive electrolyte which will not flow out
of the battery if the battery case is cracked are not subject to the provisions of this Code