#042793 Manual
9
Version 1.1
The water system can be filled with RV, non-toxic anti-freeze, which doesn’t affect copper and brass.
When you see the anti-freeze coming from the hot water tap, the heater is protected.
Specifications
Gas Type Universal LPG
Supply Pressure 2.75 kPa
Test Point Pressure 2.30 kPa
Maximum Input (propane) 13.65kW
Nominal Gas Consumption 49.14 MJ/h
Injector Ø1.06mm x 4
Efficiency > 90%
Minimum Water Flow Rate 1.5 l/min
Shut Down Water Flow rate 1.0 l/min
Maximum Water Pressure 500 kPa
Minimum Water Pressure 5 kPa
Selectable Water Temperature 35 to 60°C
Water Heating Capacity 5.0 l/min at 37°C
Supply Voltage 10.5 to 15.0 VDC
Maximum Current 1.5A