#042793 Manual
1
Version 1.1
IWH-1.5-13.5 Instantaneous Gas Water Heater
Installation and Operating Instructions
Part Numbers: 051460 (Black Door); 051459 (White Door)
The IWH-1.5-13.5 instantaneous gas water heater is designed in accordance to the Australian
Standards for installation in recreational vehicles. This water heater is not for use in houses, space
heating or marine application.
This water heater is designed to produce water with a temperature rise of 37°C above ambient, at a
flow rate of 5 litres per minute. Exceeding the flow rate will result in cooler water. If the ambient
temperature is very low (i.e. close to freezing), the water in the supply tank will be cold, resulting in
cooler than expected water.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Evacuate all persons from the caravan or RV.
Shut off the gas supply at the gas container or source.
DO NOT touch any electrical switch or use any phone or radio in the vehicle.
DO NOT start the vehicle’s engine or electric generator.
Contact the nearest gas supplier or qualified service technician for repairs.
If you cannot reach a gas supplier or qualified service technician, contact the nearest fire
station or emergency services.
DO NOT turn on the gas supply until the gas leak(s) has been repaired.
Installation, commissioning and service must be performed by a licensed gas fitter, service agency,
OEM or the gas supplier. Failure to do so will void the warranty.
WARNING:
To avoid scalding, water supplied to the shower and hand basin must pass
through a tempering valve to restrict the water temperature to 50 degrees C. We
recommend the John Guest tempering valve 12mm – code 042586.
WARNING: Installation of this product must comply with the requirements of the
Plumbing Code of Australia (PCA)
WARNING:
Do not block any pressure relief valves if fitted when installing this Hot
Water System.