Specifications
16
20 cm
T.C.A.
SENS.
AP / CH
2
1 345678910
ON
T.C.A.
SENS.
2
1 345678910
ON
AP / CH
10 OFF
Red cam
Closing end-stop microswitch
Slowing when closing end-stop adjustment
- Set dip 10 to OFF.
- Keep the “AP/CH” key pressed until the door is approximately 20 cm from the closing ledge;
- Turn the red cam until the closing end-stop microswitch is inserted and secure it with a screw.