Specifications
15
T.C.A.
SENS.
AP / CH
2
1 345678910
ON
Red cam
Closing end-stop microswitch
SENS.
2
1 345678910
ON
AP / CH
10 ON
Closing end-stop adjustment
- Set dip 10 to ON.
- Keep the "AP/CH" key pressed until the door reaches the closing ledge position.
- Turn the red cam until the closing end-stop microswitch is inserted and secure it with a screw.