opening limit switch
Keep the “APRE” button pressed and allow the door to open fully.
Press and release the “ENC/RADIO” button: the signalling LED remains on to indicate that the closing end-stop has been saved.
With the door open, position the end-stop (in the transmission guide) on the sliding runner and secure it with the screws.
Set dip-switch 1 to OFF.
Note: if the LED indicator begins to ash rapidly after dip 1 has been reset, it is necessary to repeat the procedure from the start.
NOTES
After having programmed and switched dip 1 to OFF, use the “AP/CH” key to check proper gate opening and closing.
During programming, make sure the closing end-stop has been previously memorised, otherwise the data will not be memorised.
Should the encoder malfunction or were it incorrectly connected to the opening or closing control, the motor will move briey
and then stop. The LED indicator will indicate the irregularity by ashing slowly and continuously. In this case it is necessary to
disconnect power supply from the control panel and then reconnect it.