IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG J
ENGLISH “IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS” “CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY” “THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS” 1 Legend of symbols This symbol tells you to read the section with particular care. This symbol tells you that the sections concern safety issues. 2 Intended use and application 2.
ENGLISH 4.3 Description of parts 9 1) Gate pin-housing ring 2) Gearmotor pin-housing ring 3) Gearmotor mobile ring 4) Endstop adjustment set screw 5) Release group 6) Cover 7) Operator 8) In-ground case 9) Custom key for release group 1 4 2 6 3 5 4 7 8 4.4 Dimensions The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning.
ENGLISH 5 Installation Installation must be carried out by expert qualified personnel and in full compliance with current regulations. Before installing, do the following: • Make sure you have a suitable omnipolar cut-off device with contacts more than 3 mm apart, and independent (sectioned off) power supply. • Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage.
Connections Type of cable Length of cable 1 < 10 m 3 x 1 mm2 3 x 1,5 mm2 3 x 2,5 mm2 2 x 0,5 mm2 2 x 1 mm2 2 x 1,5 mm2 2 x 0,5 mm2 2 x 0.5 mm2 2 x 0,5 mm2 4 x 0,5 mm2 4 x 0,5 mm2 4 x 0,5 mm2 2 x 0,5 mm2 2 x 0,5 mm2 2 x 1 mm2 2 x 0,5 mm2 2 x 0,5 mm2 2 x 0,5 mm2 Motor power supply 24V FROR CEI 20-22 CEI EN 50267-2-1 Photocell transmitters Photocell receivers Accessories power supply The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A.
ENGLISH 5.5 Preparing for the foundation casing The following illustrations are only examples, given that the space available for anchoring the operator and accessories may vary from gate to gate. It is up to the installer, thus, to choose the most suitable solution. - To facilitate insertion of the in-ground casing, remove the gate and lower hinges.
ENGLISH 5.6 Installing the unit N.B.: view of illustrations: outer side (to simplify the description of the mounting phases) The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning. - Insert the releases into the in-ground box and anchor them using the supplied screws. - Assemble the transmission arm with the pin-housing ring to the stuffing box, anchor them using the (M6x16) set screws and nuts.
- Insert the gearmotor into the in-ground box and anchor it using bolts and washers. N.B.: Place the gearmotor’s pin-housing ring exactly below that of the gate pin and facing the same direction. Gate pin-housing ring UNI 5739 M10x25 Gearmotor pinhousing ring WasherØ10x20 - Attach the gearmotor to the gate pin-housing ring. Turn the adjustment set screw and the nut at the opposite end – without tightening it completely.
The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning. ENGLISH - Set the lever of the release group to the gearmotor. 5.7 Adjusting the mechanical endstops - Before tightening the set screws to adjust the opening and closing of the gate, release the gearmotors (see paragraph for manual releasing).
Ø4,8x19 5.7 Manual release of the gearmotor - Lift the cover to the release group, insert and turn the key.Turn the release handle clockwise. - Close the door before manually moving the gate. 10 The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning.
6 Connecting to the control panel ENGLISH The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning. When making electrical connections, use the pit the shunt boxes. For further instructions concerning functions and adjustments, consult the control panels technical documentation. 1) Control panel 2) Left gearmotor 3) Right gearmotor 4) Shunt box 5) Junction pit 4 1 3 2 4 5 ZL90 Control panel , . - . %.# - . %.
Important safety instructions This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous. The manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses. Avoid working close to the hinges or other moving mechanical parts. Stay out of the opening/closing arc when operator is in motion. Do not exercise force against the motion of the operator as this could result in potentially dangerous situations.
ENGLISH 8 Maintenance The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning. 8.1 Periodic maintenance Periodic maintenance to be carried out by the end-user is as follows: wipe clean the glass surface of the photocells; check that the safety devices work properly; remove any obstructions. We suggest checking the state of lubrication and tightness of the anchoring screws on the operator.
Date Notes Segnature 8.3 Extra-ordinary maintenance The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised firms. N.B.: Any extraordinary maintenance must be performed by specialised technicians.
ENGLISH Installer’s stamp Operator name Date of job Technician’s segnature Requester’s segnature Job performed_____________________________________________________________________________________ ________________________________________________________________________________________________ Installer’s stamp Operator name The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning.
CAME UNITED KINGDOM LTD UNIT 3, ORCHARD BUSINESS PARK TOWN STREET, SANDIACRE NOTTINGHAM - NG10 5BP - U.K. Tel 0044 115 9210430 Cod. 119AU14 ver. 0.