SERIES FROG PLUS BELOW SURFACE SWING-GATE OPERATOR INSTALLATION MANUAL FROG-PM English EN
Index Intended use Limits to use ENGLISH Description Technical data Dimensions Description of parts Installation P. 4 P. 4 P. 4 P. 4 P. 4 P. 4 P. 5 P. 5 P. 5 Preliminary checks Tools and equipment Types and thicknesses of cables Standard installation Preparing the foundation box Installing the operator P. 5 Connecting to the control panel P.
WARNING! Important instructions for the safety of people: P. 3 - Manual code: 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
Legend of symbols This symbol shows parts which must be read with care. This symbol means the parts which describe safety issues. This symbol tells you what to tell the end-user. Intended use The FROG-PM operator is engineered and built by Came Cancelli Automatici S.p.A. in compliance with current safety regulations, to automate residential and aparment building siwng-gates. Any installation and use other than that specified in this manual is forbidden.
8 Dimensions P. 5 - Manual code: 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
Tools and equipment Types and thicknesses of cables Connection Cable type Cable length 1 < 10 m Cable length 10 < 20 m Cable length 20 < 30 m 230 V power supply to control panel 3G x 1.5 mm2 3G x 1.5 mm2 3G x 2.5 mm2 Motor power supply (V) 24 V 3G x 1.5 mm2 3G x 0,5 mm2 3G x 0,5 mm2 2 x 1.5 mm2 2 x 1.5 mm2 2 x 1.5 mm2 2 x 0.5 mm2 2 x 0.5 mm2 2 x 0.5 mm2 4 x 0.5 mm2 4 x 0.5 mm2 4 x 0.5 mm2 2 x 0.5 mm2 2 x 0.5 mm2 2 x 1 mm2 2 x 0,5 mm2 2 x 0.5 mm2 2 x 0.
Preparing the foundation box The following illustrations are also shown in the manual of the Frog-PC packaging, some exampels are shown, becasue the space for fastening the operator and accessories depends on the dimensions.It is up to the installer to choose the most suited solution. 500 65 0 P. 7 - Manual code: 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.
Installing the operator N. B.: orientation of illustration:right hand inside view. 10 - Mount the gate leaf by only inserting the upper hinge. Make sure the gate lead opens and closes flawlessly. 11 - With proper screws or welding fasten the gate-leaf to the transmission arm. P. 8 - Manual code: 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a.
P. 9 - Manual code: 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. ENGLISH Insert the adjusting screw into the motor-arm.How you insert the screw depends on how the operator is positioned (either on the right or the left of the gate).See drawing. LEFT SIDE RIGHT SIDE INSIDE VIEW Turn the gate leaf to ease mounting of the gearmotor.
Connecting to the control panel 1) Control panel 2) Left gear motor 3) Right gearmotor 4) Junction box 5) Junction pit 4 1 3 2 4 5 Electrical connections of the gearmotors to the control panel U V W X Y E E3 + E - + E - GREEN BROWN WHITE BLUE BROWN BLACK 230 V A.C. Power supply GREEN BROWN WHITE BLUE BLACK BROWN Connecting the 230 V A.C. gearmotor with opening delay Connecting the 230 V A.C. gearmotor with closing delay P. 10 - Manual code: 119AV70 ver. 1.
Adjusting the limit switches P. 11 - Manual code: 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. Adjust the opening mechanical endstops.Max gate leaf aperture is 110°. N. B.: orientatation of illustration right hand inside view Turn the adjusting screw (1) of the motor arm (3).
Completing assembly of the parts Mounting the cover After making the adjustments and electrical connections, rest the cover atop the foundation box and fasten it using the screws. M8x25 UNI 5933 screw Manually releasing the gate leaf The manual release lets the gate leaves open and then re-attach to close in case of a power outage. You can choose among three different release models:model A4366 with customised key, model A4365 with trilobe key and model A4364 with lever key.
P. 13 - Manual code: 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. ENGLISH Insert the key into the manual release lock and turn it counter clockwise.Open the gate leaf until it touches the opening strike. Push the gate leaf to the closed position to re-attach it to the gearmotor.
Safety instructions Important general safety instructions Do not allow children to play to loiter within the working range of the operator. Keep transitters and any other command devices away from children, to prevent the operator from being activated y mistake. Immediately stop using the operator if any anomaly is manifested.
ENGLISH P. 15 - Manual code: 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. Check that there is no vegetation within range of the photocells, and that no objects interfere with the operation of the automated gate.
Extraordinary maintenance The following table is used to log extraordinary maintenance, repair and improvement jobs done by the specialised external firms. N.B. All extraordinary maintenance jobs must be carried out by skilled technicians.
P. 17 - Manual code: 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
www.came.com www.came.it The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. English - Manual code 119AV70 ver. 1.0 03/2011 © CAME cancelli automatici s.p.a. 01_2011 CAME France S.a. 7, Rue Des Haras Z.i. Des Hautes Patures 92737 Nanterre Cedex (+33) 0 825 825 874 (+33) 1 46 13 05 00 FRANCE GERMANY CAME Automatismes S.a.