Installation manual
B
A
“MASTER”
&#
&#
&!
&!
&
"
"
"
"
, .
 #
#
#8
#8
 
43
43
   0
0
 
-/4
-/4
5 6 7
%
%8
%8
43
43
   0
0
 
-/4
-/4
 
43
43
   0
0
 
-/4
-/4
15
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
1) Coordinate the direction of gear motors “A” and 
“B”, by changing the rotation of motor “B” (see con-
nection for the gear motor and limit switches, p. 9).
2) Establish which motor, “A” or 
“B” will be the master (or pilot), 
set dip switch 14 to the ON on 
position on the control board. 
“Master” means the motor that 
controls both gates, while on 
the control board of the 2nd 
motor, position dip switch 11 to 
the ON position to place it into 
a “slave” state.
 N.B.: Make sure that the radio-
frequency board is inserted 
only into the Master board.
A
B
8 Connection of two coupled gear motors with single control 
A
4) Wire the electrical 
connections between 
the terminal boards, as 
shown in the figure.
Note: make sure that the 
automatic closing is trig-
gered by the master and 
deactivated in the slave.
5) Make sure that all the dip switches on 
the board of motor 2 are OFF, except for dip 
switch 11.
Important: adjust the limit switches of the 
motors so that the MASTER motor’s gate leaf 
closes after that of the SLAVE.
3) Wire the electrical connections 
and the normally used selections 
only on the MASTER terminal 
board;
/.
      
/.
      
“SLAVE”
“MASTER”
B
A
“SLAVE”
“MASTER”
/.
 
/.
/.
 
/.
B
/.
/.
      
“SLAVE”