User Manual
1
2
1
2
E
E
AX302304 - AX402306 - AX412306
AX71230
AX71230
AX302304
AX402306 - AX412306
Pag.
6
6 - Manual code:
119DU85
119DU85 ver.
0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Gate leaves of up to 4m
Opening
angle
A
mm
B
mm
C max
mm
E
mm
90° 130 130 70 800
120° 150 80 0 800
120° 140 100 50 800
Warning: after establishing the best point to which you will secure the gate bracket, secure the bracket to the pillar and make sure the
quotas shown in the table below are met.
Note: by increasing measure B, the opening angle and gate speed are reduced, while the gearmotor thrust is increased. By increasing
the measure A, the opening angle and gate speed are increases, while the gearmotor thrust is decreased.
Gate leaves of up to 7 m
Opening
angle
A
mm
B
mm
C max
mm
E
mm
90° 200 220 150 1100
120° 220 220 100 1100
Assemble and weld the two parts of the pillar bracket. Secure the bracket to the point you have chosen with proper plugs and screws
or - if the pillar is made of metal - weld it on.
Gate bracket
Pillar bracket